检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王萍 王卫东 杨俊贞 张晓光 WANG Ping;WANG Wei-dong;YANG Jun-zhen;ZHANG Xiao-guang(Zhanjiang Branch of Drilling&Production Co.,CNOOC Energy Technology&Services Ltd.)
机构地区:[1]中海油能源发展股份有限公司工程技术湛江分公司
出 处:《中国标准化》2024年第S1期259-263,共5页China Standardization
摘 要:本文对比李氏密度瓶法与全自动真密度分析仪法分析钻井用重晶石粉密度的试验精度以及结果偏差。结果表明,相较于李氏密度瓶法,全自动真密度分析仪法测定重晶石粉密度用时短,测试精度以及自动化程度高,对技术人员的技术水平要求较低,李氏密度瓶法与真密度法测定钻井用重晶石粉密度标准样品时结果偏差在0.005g/cm^(3)范围内,测定6批次重晶石粉样品的结果偏差在0.02g/cm^(3)范围内,仪器重复性极差值控制在0.01g/cm^(3),该方法满足GB/T 5005-2010对重晶石粉密度测试再现性(≤0.030g/cm^(3))以及重复性(≤0.022g/cm^(3))要求,可作为一种替代技术检测钻井用重晶石粉密度。The experimental accuracy and result deviation of Li’s density bottle method and fully automatic true density analyzer method in analyzing the density of barite powder for drilling were compared in this paper.The results show that compared with the Li’s density bottle method,the fully automatic true density analyzer method for measuring the density of barite powder takes less time,has higher testing accuracy and automation level,and requires lower technical level from technical personnel.The Li’s density bottle method and true density method have a deviation of 0.005 g/cm^(3)from the results of measuring the density standard sample of drilling barite powder.The deviation of the results of measuring 6 batches of barite powder samples is within the range of 0.02 g/cm^(3),and the instrument repeatability range is controlled at 0.01 g/cm^(3).This method meets the requirements of GB/T 5005-2010 for the reproducibility(≤0.030 g/cm^(3))and repeatability(≤0.022 g/cm^(3))of barite powder density testing.And it can be used as an alternative technology to detect the density of drilling barite powder.
关 键 词:密度 李氏密度瓶 全自动真密度分析仪 再现性 重复性 替代
分 类 号:TE254.4[石油与天然气工程—油气井工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7