氯气压缩机联锁系统运行稳定性优化措施  

Optimization measures for operation stability of chlorine compressor interlocking system

作  者:陈晨 吴红忠 张科伟 CHEN Chen;WU Hongzhong;ZHANG Kewei(Jiaozuo Coal Industry(Group)Kaiyuan Chemical Co.Ltd.,Jiaozuo 454191,China)

机构地区:[1]焦作煤业集团开元化工有限责任公司,河南焦作454191

出  处:《氯碱工业》2025年第2期27-29,共3页Chlor-Alkali Industry

摘  要:针对离子膜烧碱装置核心设备氯压机在运行过程中,由于联锁及传感器出现异常,联锁停机情况的原因进行分析,制定科学有效的优化方案,以减少和避免因此造成的非计划停车事故,确保离子膜烧碱装置的长期稳定运行,实现企业最佳经营效益.The causes are analyzed of the interlock shutdown during operation of the core equipment of the ion-exchange membrane caustic soda unit,i.e.the chlorine compressor,due to abnormal interlocking and abnormal conditions of sensing instruments.A scientifically effective optimization plan is proposed in order to reduce and avoid unplanned shutdown accidents caused by the interlock,ensure the long-term stable operation of the ion exchange membrane caustic soda unit,and achieve the best business efficiency of the enterprise.

关 键 词:控制仪表 氯压机 联锁 传感器 优化措施 稳定运行 

分 类 号:TQ056[化学工程]

 