检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王敏希 孟朋 WANG Min-xi;MENG Peng(LSBL Commercial Architectural Design Co.Ltd.,Ji’nan 250002,China)
机构地区:[1]山东省鲁商冰轮建筑设计有限公司,济南250002
出 处:《工程建设与设计》2025年第3期44-46,共3页Construction & Design for Engineering
摘 要:地源热泵在暖通空调应用中,可有效提高空调系统运行稳定性,对减少能源消耗及提高能源利用效率具有促进意义。基于地源热泵特点及种类,论文介绍了地源热泵在暖通空调设计中的应用方法,并提出建议,通过地埋管换热系统与热泵机组相结合,地埋管换热系统与热泵机组和冷却塔相结合,地埋管换热系统与热泵机组和辅助电锅炉相结合等措施,有效提高了地源热泵在暖通空调中的应用效率。Ground source heat pump(GSHP)can effectively improve the operating stability of air conditioning system in HVAC applications,and has promoting significance in reducing energy consumption and improving energy utilization efficiency.According to the characteristics and types of ground source heat pump,this paper introduces the application method of ground source heat pump in HVAC design,and puts foward some suggestions.Through the combination of buried pipe heat exchange system and heat pump unit,buried pipe heat exchange system and heat pump unit and cooling tower,buried pipe heat exchange system and heat pump unit and auxiliary electric boiler,etc.,the application efficiency of ground source heat pump in HVAC can be effectively improved.
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]