某水电站机组瓦温测量系统改造浅析  

Renovation of the Bearing Bushing Temperature Measurement System in Hydroelectric Units in a Hydropower Station

在线阅读下载全文

作  者:谢斌 XIE Bin(CHN Energy Dadu River Maintenance and Installation Co.,Ltd.,Leshan 614000,China)

机构地区:[1]国能大渡河检修安装有限公司,四川乐山614000

出  处:《水电与新能源》2025年第2期73-75,共3页Hydropower and New Energy

摘  要:针对某水电站6台发电机组瓦温数据异常问题,分析轴瓦测温系统存在的问题和导致测温系统故障的原因,提出了针对性的瓦温测量系统改造方案。该水电站6台发电机瓦温测量系统改造完成后,各测点工作正常,系统稳定,能满足现场运行人员监控机组运行状况的要求。In the six hydroelectric generation units a hydropower station,abnormal bearing bushing temperature data is observed.Possible problems in the bearing bushing temperature measurement system and the causes of these problems are analyzed.Corresponding renovation scheme is then proposed.After the renovation of the bearing bushing temperature measurement system of the units,all measuring points are working normally and stably.The requirements for on-site operators to monitor the operation status of the units are satisfied.

关 键 词:水电机组 瓦温测量系统 结构 故障 改造 

分 类 号:TM312[电气工程—电机]

 