水电站机组环形吊运行机构打滑原因及对策  

Analysis and Treatment of the Slipping of Ring Crane Operating Mechanism for Units in Hydropower Stations

作  者:樊小波[1] 张兆礼 刘文忠[1] 石教锐 董万里[1] 刘文亮[1] FAN Xiaobo;ZHANG Zhaoli;LIU Wenzhong;SHI Jiaorui;DONG Wanli;LIU Wenliang(Xiluodu Hydropower Plant,China Yangtze Power Co.,Ltd.,Zhaotong 657300,China)

机构地区:[1]中国长江电力股份有限公司溪洛渡水力发电厂,云南昭通657300

出  处:《水电与新能源》2025年第2期83-85,共3页Hydropower and New Energy

摘  要:环形吊运行机构打滑直接影响机组检修效率。结合典型案例,剖析了水电站机组环形吊运行机构打滑的原因,提出了针对性的处理措施,为同类型设备的相似故障处理提供参考。Slipping of the ring crane operating mechanism directly affects the maintenance efficiency of the units.Based on typical cases,possible reasons of the slipping problem in ring crane operating mechanism of hydro-turbine units are analyzed.Corresponding treatment measures are proposed.It could provide reference for the treatment of similar faults in equipment of the same type.

关 键 词:环形吊 运行机构 打滑 油泥 间隙 

分 类 号:TV734[水利工程—水利水电工程]

 