含同杆并架配电网接地故障特征分析及选线方法研究  

Characteristics Analysis of Ground Fault in Distribution Network with Double-Circuit Lines on the Same Tower and Research on Line Selection Method

在线阅读下载全文

作  者:葛景 叶建伟 韩连山 王新宝[1] 俞秋阳[1] 刘阿荣 罗皓 王明月 梁永亮[4] GE Jing;YE Jianwei;HAN Lianshan;WANG Xinbao;YU Qiuyang;LIU Arong;LUO Hao;WANG Mingyue;LIANG Yongliang(NR Electric Co.,Ltd.,Nanjing Jiangsu 211102,China;Alxa Power Supply Branch,Inner Mongolia Power(Group)Co.,Ltd.,Alxa League Inner Mongolia 750306,China;Inner Mongolia Guohe Electric Power Co.,Ltd.,Huhhot Inner Mongolia 010060,China;School of Electrical Engineering,Shandong University,Jinan Shandong 250061,China)

机构地区:[1]南京南瑞继保电气有限公司,江苏南京211102 [2]内蒙古电力(集团)有限责任公司阿拉善供电分公司,内蒙古阿拉善盟750306 [3]内蒙古国合电力有限责任公司,内蒙古呼和浩特010060 [4]山东大学电气工程学院,山东济南250061

出  处:《湖北电力》2024年第5期80-88,共9页Hubei Electric Power

基  金:内蒙古电力(集团)有限责任公司科技项目(项目编号:2022JBGS0044)。

摘  要:配电网常对已有线路加工改造,将单回线路改造为同杆并架双回线路以满足日益增长的供电需求,为实现含同杆并架线路的10kV中压配电系统接地故障可靠选线,从同杆并架双回线电容矩阵出发,对扩展卡伦鲍尔变换和相应等值电路进行分析,结合仿真探究了含同杆并架双回线配电网的接地故障特征,与相同架设高度的非同杆并架线路进行了对比,在此基础上提出了一种适用于含同杆并架双回线的中性点不接地配电网选线方法,将选线过程分为对每组同杆并架线路选线的“界内选线”和对其他线路进行选线的“界外选线”两部分。经仿真验证该方法能对含同杆并架线路的中性点不接地的配电网单相接地故障有效选线。Distribution networks often modify the existing lines,transforming single-circuit lines into double-circuit lines on the same tower to meet the increasing demand for power supply.In order to achieve reliable selection for ground faults of 10 kV medium-voltage distribution systems with double-circuit lines,this paper starts from the capacitance matrix of the double-circuit lines on the same tower and analyzes the extended Karenbauer transform and corresponding equivalent circuits,then combines with simulation to explore the ground fault characteristics of distribution networks with double-circuit lines on the same tower,and make a comparison with the single-circuit lines of the same erection height,and finally on this basis,proposes a method of line selection suitable for neutral ungrounding distribution network with double-circuit lines on the same tower.In the proposed method,the selection process is divided into two parts:"within boundary line selection"for each group of double-circuit lines on the same tower,and"out-of-bound line selection"for other lines.The simulation verification is carried out to show that the proposed method can be used for effective line selection of single-phase ground faults in neutral ungrounding distribution network with double-circuit lines on the same tower.

关 键 词:同杆并架双回线 中性点不接地 单相接地故障 配电网选线 故障仿真 

分 类 号:TM73[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象