自排流道隔墩对轴流泵装置性能影响试验  

Experiment on the influence of self-draining partition pier on the performance of axial flow pump

作  者:沈毅韵 陆伟刚[1] 刘健峰 杨晓春 张芳芳 SHEN Yiyun;LU Weigang;LIU Jianfeng;YANG Xiaochun;ZHANG Fangfang(College of Hydraulic Science and Engineering,Yangzhou University,Yangzhou 225000,China;Anhui Survey and Design Institute of Water Resources and Hydropower,Hefei 230088,China)

机构地区:[1]扬州大学水利科学与工程学院,江苏扬州225000 [2]安徽省水利水电勘测设计研究总院有限公司,合肥230088

出  处:《南水北调与水利科技(中英文)》2025年第1期166-176,共11页South-to-North Water Transfers and Water Science & Technology

基  金:国家自然科学基金项目(51779215);江苏省水利科技项目(2022060);江苏南水北调科技研发项目(JSNSBD202302)。

摘  要:为探究具有较长自排流道的立式轴流泵装置的性能改良措施,以陈郢泵站为研究对象,在自排流道中设置隔墩并进行模型试验对比研究,以模型试验结果为基础优选适用于该泵站的设计方案。结果表明:设置隔墩后泵装置全扬程范围内的效率均向上小幅度增长,其中,在设计扬程工况下泵装置效率由71.9%提升至73.0%,临界空化余量由8.7 m降至8.2 m,泵装置的能量和空化性能均得到改善;设置隔墩后泵装置在各角度工况下的飞逸性能无明显变化,经试验测出的泵装置的最大飞逸转速满足水泵安全运行要求;设置隔墩后各角度工况下的喇叭口进口在大流量工况下的压力脉动振幅值变小,振幅波动变得更加稳定,实时水压脉动的振幅值和平均峰峰值也相对减小。故在自排流道中设置隔墩可以改善装置的外特性和压力脉动特性,建议泵站优先采用该方案。Large low-head pumping stations are widely constructed in the Yangtze River Delta, situated along both rivers and lakes. These stations are an important part of China's pumping station project, operating under low head,with large flow capacities and a high degree of automation. Due to its long and changeable inlet and outlet channels,the key to reduce the hydraulic loss in their channels was to improve the operation efficiency of drainage pumping stations. At present, due to terrain and other reasons, many low-head drainage pumping stations behind levees set up long dike box culverts as self-discharging channels. When large low-head drainage pumping stations with long self-discharging channels operate under pumping conditions, part of the water flowing from the rear side of the horn into the horn will rotate at low speed in the self-discharging channel behind the inlet channel to form a return zone,which exacerbates the vortex band and affect the performance of the device.Chenying pumping station was took as the research object to explore the improvement measures for the performance of the vertical axial flow pump with a long self-draining channel, with the partition pier set in the selfdraining channel and a comparative study on the model test was conducted. The actual operation of the device could be accurately analyzed and the design scheme suitable for the pumping station was optimized based on the results of the model test of the pump device. Combining the results of the comparison between the original scheme and the optimized scheme, the targeted rectification optimization scheme was provided for the pumping station.The results indicated that the efficiency increased slightly in the full head range of the device after setting the partition pier and the device efficiency increased from 71.9% to 73.0% under the design head condition when the critical cavitation margin decreased from 8.7 m to 8.2 m. The addition of partition pier had little influence on the runaway performance of the device at various angles a

关 键 词:隔墩 泵装置 进水流道 喇叭口 自排流道 压力脉动 外特性 

分 类 号:TV675[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象