检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:魏巍[1,2] 王羽泽 米家宝 黄静秋 WEI Wei;WANG Yuze;MI Jiabao;HUANG Jingqiu(National Key Laboratory of Vehicular Transmission,Beijing Institute of Technology,Beijing 100081,China;Beijing Institute of Technology Chongqing Innovation Center,Chongqing 401120,China;Beijing Benz Automobile Co.Ltd.,Beijing 102600,China;Jianglu Machinery Electronics Group Co.Ltd.,Xiangtan 411100,Hunan China)
机构地区:[1]北京理工大学车辆传动国家重点实验室,北京100081 [2]北京理工大学重庆创新中心,重庆401120 [3]北京奔驰汽车有限公司,北京102600 [4]江麓机电集团有限公司,湖南湘潭411100
出 处:《华中科技大学学报(自然科学版)》2024年第12期37-44,共8页Journal of Huazhong University of Science and Technology(Natural Science Edition)
基 金:国家部委创新计划资助项目(237099000000170009)。
摘 要:针对变矩器解锁工况下的缓速器稳态制动转矩预测问题,考虑变矩器反传工况,结合计算流体动力学(CFD)仿真模型与试验数据,建立液压-液力联合仿真模型.探究缓速器的泵吸效应及出口压力变化,获取液压-液力系统的压力流量特性与缓速器的充液特性,开展台架试验验证.结果表明:缓速器工作时具有泵吸效应,使系统流量增加;液压-液力联合仿真模型得到的压力流量特性与试验数据相符合,仿真数据与试验结果相对误差不超过10%;缓速器的充液率与出口压力、动轮转速相关,通过联合仿真模型预测的充液率与试验误差不超过5%;充液率随出口压力的增加而增加,随动轮转速的增加而减小.In addressing the task of predicting the steady-state braking torque of the retarder under torque converter unlocking state,the hydraulic-hydrodynamic co-simulation model was constructed,which considered the reverse transmission condition of the torque converter and combined the computational fluid dynamics(CFD)simulation model with test data.Considering the pumping effect of the retarder and the change of outlet pressure,the pressure-flow characteristic and the filling characteristic of the retarder was obtained,and bench test were carried out.The results show that:the retarder has a pumping effect,which increases the flow of the system;the pressure and flow characteristics obtained by the hydraulic-hydraulic co-simulation model are consistent with the test data,and the relative error between the simulation data and the test results is not more than 10%.The filling rate of the retarder is related to the outlet pressure and the speed of the rotor.The error of the filling rate predicted by the co-simulation model and the test is not more than 5%,the filling rate increases as the outlet pressure increase and the speed of the rotor decreases.
关 键 词:液力缓速器 充液率 解锁工况 液压-液力系统 台架试验
分 类 号:TH137[机械工程—机械制造及自动化]