风幕系统对地下车库防结露效果分析  

Analysis of Effect of Air Curtain System on Anti-condensation of Underground Garage

在线阅读下载全文

作  者:王哲 王晓明 刘治鸣 李建伟 鲍玲玲 WANG Zhe;WANG Xiaoming;LIU Zhiming;LI Jianwei;BAO Lingling(School of Energy and Environmental Engineering,Hebei University of Engineering,Handan,Hebei 056038,China;Handan Rongke Real Estate Development Group Co.,Ltd.,Handan,Hebei 056000,China)

机构地区:[1]河北工程大学能源与环境工程学院,河北邯郸056038 [2]邯郸市荣科房地产开发集团有限公司,河北邯郸056000

出  处:《河北工程大学学报(自然科学版)》2025年第1期97-104,共8页Journal of Hebei University of Engineering:Natural Science Edition

基  金:河北省自然科学基金资助项目(E2023402072)。

摘  要:针对因地下车库结露造成的汽车打滑、壁面墙皮脱落、地面发霉等问题,以邯郸某车库为例,通过对实际监测数据进行分析,运用FLUENT软件对车库加装风幕系统进行模拟,设置不同的送风速度,观察车库内空气的温湿度云图状况,并与自然通风工况下车库内温湿度进行对比分析,提出防治措施及通风运行策略。模拟结果表明:当风幕系统送风速度分别为2、4 m/s时,其车库内空气温度分别提升0.7℃、1.2℃,其相对湿度分别降低5.5%、8.9%,露点温度分别降低至13.92℃、13.73℃;送风速度由4 m/s增大至6 m/s时,其变化与风速由2 m/s增大至4 m/s时一致,此时,露点温度降低至13.52℃,低于壁面温度14℃与地面温度15℃,防结露效果明显。In response to the problems of car slippage,wall peeling,and ground mold caused by condensation in underground garages,taking a garage in Handan as an example,the actual monitoring data was analyzed.Fluent software was used to simulate the installation of an air curtain system in the garage,set different air supply speeds,observe the temperature and humidity cloud map of the air inside the garage,and compare and analyze it with the temperature and humidity inside the garage under natural ventilation conditions.Preventive measures and ventilation operation strategies were proposed.The simulation results show that when the air supply speed of the air curtain system is 2 and 4 m/s respectively,the air temperature in the garage increases by 0.7℃and 1.2℃respectively,and the relative humidity decreases by 5.5%and 8.9%respectively,and the dew point temperature decreases to 13.92℃and 13.73℃respectively;When the air supply speed increases from 4 m/s to 6 m/s,the change is consistent with the increase in wind speed from 2 m/s to 4 m/s.In this case,the dew point temperature decreases to 13.52℃,which is 14℃lower than the wall temperature and 15℃lower than the ground temperature,and the anti-condensation effect is significant.

关 键 词:地下车库 结露 风幕系统 温湿度 通风 

分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象