深度处理技术在城镇污水处理厂提标改造中的工程应用  

Engineering Application of Advanced Treatment Technology in Upgrading and Renovating Urban Sewage Treatment Plants

在线阅读下载全文

作  者:向伟 简浩 岳中秋 王英蓉 范晓露 朱春游 刘君 XIANG Wei;JIAN Hao;YUE Zhongqiu;WANG Yingrong;FAN Xiaolu;ZHU Chunyou;LIU Jun(Hunan Aerospace Kaitian Water Co.,Ltd.,Changsha 410100,China)

机构地区:[1]湖南航天凯天水务有限公司,长沙410100

出  处:《中国资源综合利用》2025年第2期275-277,共3页China Resources Comprehensive Utilization

摘  要:四川省某城镇污水处理厂出水水质原来执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级B标准,随着城镇污水排放要求的提高,提标改造势在必行。该污水处理厂原采用“格栅井+调节池+水解酸化池+接触氧化池+二沉池+紫外线消毒”工艺,结合实际出水水质数据中总氮超标的特点,在原二沉池后、紫外线消毒渠之前增加“高效沉淀池+反硝化滤池”组合。项目出水满足《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级A标准,可为同类型城镇污水处理厂提标改造提供设计参考。The effluent quality of a certain urban sewage treatment plant in Sichuan province used to comply with the first level B standard of the Pollutant Discharge Standards for Urban Sewage Treatment Plants (GB 18918—2002),with the increasing requirements for urban sewage discharge,it is necessary to raise the standard and make improvements.The sewage treatment plant originally used the process of “grid well + regulating tank + hydrolysis acidification tank + contact oxidation tank + secondary sedimentation tank + ultraviolet disinfection”,combined with the characteristic of total nitrogen exceeding the standard in actual effluent water quality data,a combination of “high-efficiency sedimentation tank +denitrification filter” was added after the original secondary sedimentation tank and before the ultraviolet disinfection channel.The effluent of the project meets the first level A standard of the Pollutant Discharge Standards for Urban Sewage Treatment Plants (GB 18918—2002),which can provide design reference for the upgrading and renovation of similar urban sewage treatment plants.

关 键 词:深度处理技术 城镇污水处理厂 提标改造 高效沉淀池 反硝化滤池 

分 类 号:X703.1[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象