介入手术导管床保护性约束带设计及应用  

Design and application of protective restraint band used for the interventional catheter bed

在线阅读下载全文

作  者:章雁[1] 金浙夏 吴春俏 沈富女[2] 沈珑珑[1] 陈璐民 庄一渝[2] ZHANG Yan;JIN Zhexia;WU Chunqiao;SHEN Funv;SHEN Longlong;CHEN Lumin;ZHUANG Yiyu(Department of Interventional Radiology,Affiliated Run Run Shaw Hospital,School of Medicine,Zhejiang University,Hangzhou,Zhejiang Province 310016,China)

机构地区:[1]浙江大学医学院附属邵逸夫医院放射科,浙江杭州310016 [2]浙江大学医学院附属邵逸夫医院护理部,浙江杭州310016

出  处:《介入放射学杂志》2025年第2期197-199,共3页Journal of Interventional Radiology

摘  要:目的设计自制一种DSA介入手术导管床保护性约束带,评价其应用效果。方法自制约束带由约束单本体、第1活动带和第2活动带组成。选择2022年10月至2023年3月在浙江邵逸夫医院接受介入手术治疗的200例患者为应用对象,其中100例为对照组(不使用约束带),另100例为实验组(使用自制约束带)。对比两组患者因素导致的手术中断时间、约束相关不良事件发生率。结果实验组手术中断时间显著低于对照组[(0.26±0.12)min比(1.46±0.50)min],差异有统计学意义(t=-23.570,P<0.01)。实验组、对照组约束相关不良事件发生率分别为0、7%,差异有统计学意义(χ^(2)=6.380,P=0.012)。结论自制介入手术导管床保护性约束带可降低约束相关不良事件发生率,提升手术效率。Objective To independently design a protective restraint band used for the interventional catheter bed and to evaluate its application effect.Methods The self-designed restraint belt consisted of a restraint belt body,first movable band and second movable band.A total of 200 patients,who received interventional operation at the Affiliated Run Run Shaw Hospital,School of Medicine of Zhejiang University of China from October 2022 to March 2023,were collected for this study.The patients were divided into the study group(n=100,using the self-designed restraint belt)and the control group(n=100,not using the self-designed restraint belt).The duration of surgical interruption due to patient′s factors and the incidence of restraint belt-related adverse events were compared between the two groups.Results The duration of surgical interruption of the study group was(0.26±0.12)min,which was significantly shorter than(1.46±0.50)min in the control group,the difference was statistically significant(t=-23.570,P<0.01).The incidence of restraint belt-related adverse events in the study group and the control group was 0%and 7%respectively,the difference was statistically significant(χ~2=6.380,P=0.012).Conclusion The protective restraint band used for the interventional catheter bed can reduce the incidence of restraint belt-related adverse events and improve surgical efficiency.

关 键 词:介入放射学 身体约束 手术中护理 

分 类 号:R473.6[医药卫生—护理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象