Development of a Shoelace Tensile Testing System and Investigation into the Effects of Different Running Speeds on Shoelace Tensile Variation  

在线阅读下载全文

作  者:Shutao Wei Xinyu Guo Shaocong Zhao Biao Yan Lingjun Li Jiahao Pan Li Li 

机构地区:[1]Department of Physical Education,Xiamen University of Technology,Xiamen,361024,China [2]361°(CHINA)Co.,Ltd,Jinjiang,362261,China [3]College of Art and Design,Shaanxi University of Science&Technology,Xi’an,710061,China [4]China Leather and Footwear Industry Research Institute(Jinjiang)Co.,LTD,Jinjiang,362200,China [5]Center for Orthopedic and Biomechanics Research,Boise State University,Boise,83725,USA [6]Department of Health Sciences and Kinesiology,Georgia Southern University,Statesboro,GA,30460,USA

出  处:《Journal of Bionic Engineering》2025年第1期214-225,共12页仿生工程学报(英文版)

摘  要:This study investigated the validity and sensitivity of a custom-made shoelace tensile testing system.The aim was to analyze the distribution pattern of shoelace tension in different positions and under different tightness levels during running.Mechanical tests were conducted using 16 weights,and various statistical analyses,including linear regression,Bland-Altman plots,coefficient of variation,and intraclass correlation coefficient,were performed to assess the system’s validity.Fifteen male amateur runners participated in the study,and three conditions(loose,comfortable,and tight)were measured during an upright stance.The system utilized VICON motion systems,a Kistler force plate,and a Photoelectric gate speed measurement system.Results showed a linear relationship between voltage and load at the three sensors(R2≥0.9997).Bland-Altman plots demonstrated 95%prediction intervals within±1.96SD from zero for all sensors.The average coefficient of variation for each sensor was less than 0.38%.Intraclass correlation coefficient values were larger than 0.999(p<0.0001)for each sensor.The peak tension of the front shoelace was greater than that of the front and middle when the shoelace was loose and tight.The rear shoelace had the highest tension force.The study also found that shoelace tension varied throughout the gait cycle during running.Overall,this research provides a novel and validated method for measuring shoelace tensile stress,which has implications for developing automatic shoelace fastening systems.

关 键 词:Force sensor Shoelace Tensile stress Upright stance Running shoes 

分 类 号:TH871[机械工程—仪器科学与技术] R318[机械工程—精密仪器及机械]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象