检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李政 LI Zheng(Nanjing Qingquan Construction Technology Co.,Ltd.,Nanjing 211200,China)
机构地区:[1]南京清泉建设科技股份有限公司,江苏南京211200
出 处:《现代建筑电气》2025年第1期47-51,共5页Modern Architecture Electric
摘 要:城市区域增压泵站具有保障区域供水稳定的重要作用,应采用安全可靠的供电方式。采用交直流一体化电源系统,可以为区域增压泵站提供可靠的电力供应。结合石湫增压泵站项目,分析交直流系统接线方式并对直流系统参数进行计算,结果验证了交直流一体化电源系统在区域增压泵站的可实施性。Urban district booster pump stations is playing an important role in ensuring economic and political stability in the region,and should adopt a safe and reliable power supply method.A hybrid AC/DC power supply system can provide reliable power supply and management capabilities for the regional booster pump station.Combining the Shiqiu booster pump station project,it analyzes the connection method of the AC/DC system and the calculation of DC system parameters.The results verify the feasibility of the hybrid AC/DC power supply system in regional booster pump stations.