摘 要:针对地铁车辆基地上盖框架-剪力墙结构,基于Opensees提出了一种可以考虑抗震结构、15m层间单体隔震结构、9m层间单体隔震结构和9m层间整体隔震结构等多种结构方案的简化弯剪型多质点模型以及相应的参数标定方法,并通过与某地铁车辆基地上盖框架单体有限元分析结果的对比,验证了所提出计算模型的准确性。对比15m层间单体隔震结构和9m层间整体隔震结构的分析结果后发现,15m层间单体隔震质量参与系数最大的振型为以盖下结构振动为主的第三阶振型,而9m层间整体隔震结构质量参与系数最大的振型为周期最长的一阶隔震振型。弹塑性时程分析结果表明,9m层间整体隔震结构相比于15m层间单体隔震结构,能够减小38.4%的盖上结构层间剪力和71.4%的盖下结构层间剪力,同时使得最大弹塑性层间位移角减小50%。A simplified analysis method for upper cover frame-shear wall structures of urban rail transit was proposed based on the flexure-shear type MDOF model in Opensees.This method can consider various structural schemes of upper cover frame-shear wall structure,including seismic-resistant structure,15-meter-story individual isolation structure,9-meter-story individual isolation structure and 9-meter-story monolithic isolation structure.The corresponding parameter calibration method was also presented.The accuracy of the proposed method was verified by comparing analysis with the finite element analysis results of an upper cover shear wall structure.Comparing the analysis results of the 15-meter-story individual isolation structure and the 9-meter-story individual isolation structure,it was found that the dominant vibration mode with the highest participation coefficient of the former is the third mode,mainly characterized by the vibration of the upper structure.On the other hand,that of the latter is the first mode,which has the longest period and mainly characterized by the vibration of the structure above isolation layer.The results of the elastoplastic seismic time history analysis show that the 9-meter-story individual isolation structure can reduce the inter-story shear force of the upper structure by 38.4%and that of the substructure by 71.4%compared to the 15-meter-story individual isolation structure,with 50%reduction of the inter-story drift.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7