Application of a new cavity-loaded factor calibration algorithm on the Test Stand 2 facility at the European Spallation Source  

在线阅读下载全文

作  者:Jinying Ma Lijuan Yang Feng Qiu Muyuan Wang Rihua Zeng Chengye Xu Jingwei Yu Cecilia Maiano Philippe Goudket Bruno Lagoguez Paolo Pierini Yuan He 

机构地区:[1]Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou,730000,China [2]School of Nuclear Science and Technology,University of Chinese Academy of Sciences,Beijing,100049,China [3]European Spallation Source ERIC,22100,Lund,Sweden

出  处:《Radiation Detection Technology and Methods》2024年第4期1520-1530,共11页辐射探测技术与方法(英文)

基  金:supported by the project of Large Research Infrastructures“National Natural Science Foundation of China”(Grant No.U22A20261);the“Studies of intelligent LLRF control algorithms for superconducting RF cavities”(Grant No.E129851YR0);the“National Natural Science Foundation of China”(Grant No.12205344).

摘  要:Purpose Precise measurements of the cavity-loaded quality factor(Q_(L))are essential for monitoring the performance of superconducting radio frequency cavities.The conventional“field-decay method”cannot be used to measure Q_(L)accurately when the impedance is mismatched.Researchers at the China ADS Front End Demo Linac(CAFe)therefore introduced a new Q_(L)calibration algorithm for mismatched impedance conditions,which they validated through testing at the CAFe facility.The Test Stand 2(TS2)facility at the European Spallation Source(ESS),which is equipped with a high-power circulator having an adjustable reflection coefficient,provides increased experimental flexibility for validating the proposed CAFe algorithm.The present study further validates the proposed algorithm at the ESS TS2 facility.Methods In this study,we utilized the CAFe algorithm to measure Q_(L)at the ESS TS2 facility in the presence of mismatched impedance.The CAFe algorithm is a modified version of the“field-decay method,”which is based on the cavity differential equation.A more concise alternative derivation of the proposed CAFe algorithm is given in Appendix.The experimental setup at the TS2 facility enables the adjustment of the circulator bias current to vary the reflection coefficient,thereby introducing an impedance mismatch.Our primary focus here is to calibrate the actual values Q_(L)and the cavity detuning Q_(L)under these mismatch conditions.Results Our results reconfirm the effectiveness of the CAFe algorithm by accurately calibrating Q_(L)andΔf at the ESS TS2 facility,even when the impedance is mismatched.Our successful calibration of Q_(L)andΔf under mismatched conditions highlights the practicality and reliability of the CAFe proposed algorithm.When calibrating the cavity half bandwidth and detuning,the Lorentz force detuning and direct current offset may introduce uncertainties of approximately±5 Hz and±4 Hz,respectively.

关 键 词:Loaded quality factor Field decay method MISMATCH Calibration 

分 类 号:O572[理学—粒子物理与原子核物理]

 