自然散热边界条件下吸热器疏盐过程温度场计算  

Calculation of Temperature Field during Salt Drainage Process of Heat Receiver under Natural Heat Dissipation Boundary Conditions

作  者:宋永富[1,2] 李琪[1,2] 张天云 SONG Yongfu;LI Qi;ZHANG Tianyun(Harbin Boiler Company Limited,Harbin 150046,China;State Key Laboratory of Low-carbon Thermal Power Generation Technology and Equipments(Harbin Boiler Company Limited),Harbin 150046,China)

机构地区:[1]哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046 [2]低碳热力发电技术与装备全国重点实验室(哈尔滨锅炉厂有限责任公司),黑龙江哈尔滨150046

出  处:《锅炉制造》2025年第2期45-47,50,共4页Boiler Manufacturing

摘  要:吸热器在停机疏盐时,容易发生冻堵,本文通过模拟与理论计算两种手段对自然散热边界条件下熔盐温度变化过程进行分析,得出熔盐发生冻堵的原因,并从设计、运行角度给予了优化建议。Salt freezing blockage is prone to occur during the process of salt draining when the heat receiver is shutting down.Oriented to this problem,the temperature change process of molten salt under natural heat dissipation boundary condition is analyzed by simulation and theoretical calculation simultaneously.The reason of molten salt freezing blockage is given,and optimization suggestions are given from the perspectives of design and operation.

关 键 词:光热发电 吸热器 冻堵 

分 类 号:TM615[电气工程—电力系统及自动化]

 

参考文献: