检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张俊峰 田家铭[1] 王黎明 王跃社 信敏[2] Zhang Junfeng;Tian Jiaming;Wang Liming;Wang Yueshe;Xin Min(State Key Laboratory of Multiphase Flow in Power Engineering,Xi'an Jiaotong University,Xi'an 710049,China;Northwest Engineering Corporation Limited,Power China,Xi'an 710065,China;Shaanxi Electric Power Design Institute Co.,Ltd.,China Energy Engineering Group,Xi'an 10000,China)
机构地区:[1]西安交通大学动力工程多相流国家重点实验室,西安710049 [2]中国电建集团西北勘测设计研究院有限公司,西安710065 [3]中国能源建设集团陕西省电力设计院有限公司,西安710000
出 处:《西北水电》2025年第1期117-124,共8页Northwest Hydropower
基 金:陕西省重点研发计划(2024GX-YBXM-522)。
摘 要:在大规模光热电站参与调峰运行的背景下,探究太阳能光热电站熔盐蒸汽发生系统的运行特性和安全性尤为重要。为了分析太阳能光热电站熔盐蒸汽发生系统的运行特性和安全性,采用效能-传热单元数方法建立了某50 MW光热电站熔盐蒸汽发生系统的热预测模型,使用实际运行数据修正了过热器、再热器、蒸发器和预热器的效能-传热单元数经验关联式,预测误差低于2.7%,探究了熔盐流量和换热面积对系统换热性能的影响,并提出了两种控制预热器运行安全的设计方案。结果表明:蒸发器的总换热系数受到熔盐流量的影响最大,可以通过增大熔盐流量提高系统换热量,但提升效果有限,增加过热器和再热器的面积可改善实际运行主蒸汽参数以达到最佳值;同时对蒸发换热系统中预热器安全运行进行了分析,提出了预热器安全运行措施。Against the backdrop of large-scale solar thermal power plants participating in peak regulation operation,it is particularly important to explore the operation characteristics and safety of the molten salt steam generation system in solar thermal power plants.In order to analyze the operation characteristics and safety of the molten salt steam generation system in a solar thermal power plant,the effectiveness-number of transfer units method is adopted to establish a thermal prediction model of the molten salt steam generation system in a 50 MW solar thermal power plant.The empirical correlation equations of the effectiveness-number of transfer units for the superheater,reheater,evaporator and preheater are corrected using the actual operation data,and the prediction error is less than 2.7%.The influence of the molten salt flow rate and the heat transfer area on the heat transfer performance of the system is explored,and two design schemes for controlling the operation safety of the preheater are proposed.The results show that the total heat transfer coefficient of the evaporator is most affected by the molten salt flow rate.The heat transfer amount of the system can be increased by increasing the molten salt flow rate,but the improvement effect is limited.Increasing the areas of the superheater and the reheater can improve the actual operation parameters of the main steam to reach the optimal values.At the same time,the safe operation of the preheater in the evaporative heat transfer system is analyzed,and measures for the safe operation of the preheater are proposed.
分 类 号:TK512[动力工程及工程热物理—热能工程] TK2
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7