检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:秦玉强 Qin Yuqiang(The Fourth Construction Co.,Ltd.of China Electronics System Engineering,Beijing 100160,China)
机构地区:[1]中国电子系统工程第四建设有限公司,北京100160
出 处:《山西建筑》2025年第8期97-100,共4页Shanxi Architecture
摘 要:以某维修车间为研究对象,调研了车间内污染物组成,实地测试了车间内污染物浓度,并把污染物测试浓度与相关国家标准进行了对比分析;对维修车间的通风系统进行了数值模拟,计算出了维修车间需要的通风量,并根据模拟结果,对维修车间排风口布置给出了优化方案。通过对维修车间内污染物浓度的实测、分析、模拟和研究,得出机械通风系统的改造优化方案,为同类型建筑的暖通设计及改造提供有力的理论依据和实践支撑。Taking a maintenance workshop as the research object,conducted research on the composition of pollutants in the workshop,tested the concentration of pollutants in the workshop on site,and a comparative analysis was conducted between the tested concentration of pollutants and relevant national standards;Numerical simulation was conducted on the ventilation system of the maintenance workshop,calculated the ventilation required for the maintenance workshop,and based on the simulation results,an optimization plan has been proposed for the layout of exhaust vents in the maintenance workshop.By measuring,analyzing,simulating,and studying the concentration of pollutants in the maintenance workshop,develop an optimized renovation plan for the mechanical ventilation system,provided strong theoretical basis and practical support for HVAC design and renovation of buildings of the same type.
关 键 词:维修车间 污染物浓度测试 通风系统优化 数值模拟
分 类 号:TU834.53[建筑科学—供热、供燃气、通风及空调工程]