检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:胡继超 潘卓尔 何建 周厚磊 俞光荣[2] HU Ji-chao;PAN Zhuo-er;HE Jian;ZHOU Hou-lei;YU Guang-rong(Department of Orthopaedic Trauma and Joint Surgery,Zhejiang Rongjun Hospital,Jiaxing,Zhejiang 314000,China;Tongji Hospital,Tongji University,Shanghai 200065,China)
机构地区:[1]浙江省荣军医院关节创伤科,浙江嘉兴314000 [2]同济大学附属同济医院,上海200065
出 处:《中国矫形外科杂志》2025年第4期369-372,共4页Orthopedic Journal of China
摘 要:[目的]测量胫骨远端关节面穹隆前后置钉的安全高度和角度。[方法]用医学影像浏览器测量100例(男性组64例、女性组36例)踝关节MRI矢状位T2加权像上胫骨远端关节面穹隆顶点的软骨下骨与胫骨远端关节面前、后唇下缘连线的距离及胫骨远端关节面前唇弧形的切线与前、后唇连线的夹角。比较分析男女组、左右侧组的差别。[结果]男性右侧关节面穹隆顶与前后唇连线距离显著高于女性,差异具有统计学意义[(5.6±0.9)mm vs(5.1±0.8)mm,P=0.035]。男性的左侧与右侧的前唇切线与前后唇连线夹角均低于女性,但差异无统计学意义(P>0.05)。男性与女性中,左侧的关节面穹隆顶与前后唇连线距离均高于右侧,但差异无统计学意义(P>0.05)。男性[(37.6±5.0)°vs(32.2±8.2)°,P=0.003]和女性[(37.8±4.6)°vs(32.7±7.3)°,P=0.026]的左侧的前唇切线与前后唇连线夹角均显著大于右侧。[结论]踝关节远端前后向置入螺钉时,螺钉下缘应至少位于前唇边缘上方约7 mm,男性右侧高于女性右侧。如置入更远端螺钉,应向胫骨近端倾斜至少42°,男女性左侧均高于右侧。[Objective]To measure the safe height and angle of anteroposterior screw placement in distal articular dome of the tibia.[Methods]The vertical distance of distal articular surface dome to the connecting line of the lowest point of the anterior and posterior tibiallips,and the angle between the tangent line of the anterior and posterior lips of the distal tibia were measured on the T2 weighted MRI imagines in 100 patients,including 64 males and 36 females.The differences between male and female groups and left and right groups werecompared and analyzed.[Results]The male had significantly greater vertical distance of distal articular surface dome to the connecting lineof the lowest point of the anterior and posterior tibial lips on the right side than the female,with statistically significant difference[(5.6±0.9)mm vs(5.1±0.8)mm,P=0.035].The male had less angle between the tangent line of the anterior and posterior lips of the distal tibia on theleft and right sides than the female,but the difference was not statistically significant(P>0.05).In both male and female,the vertical distance of distal articular surface dome to the connecting line of the lowest point of the anterior and posterior tibial lips on the left side wasgreater than that on the right side,despite of the fact that difference was not statistically significant(P>0.05).Both male[(37.6±5.0)°vs(32.2±8.2)°,P=0.003]and female[(37.8±4.6)°vs(32.7±7.3)°,P=0.026]had significantly greater angle between the tangent line of the anterior and posterior lips of the distal tibia on the left side and the right side.[Conclusion]As anteroposterior screw placement on the distaltibia,the lower edge of the screw should be at least 7 mm above the edge of the anterior lip of the tibia,which in male should be higher thanthat in the female on the right side.If further longer screws are implanted,tilting the screw at least 42°to the proximal tibia,with the leftside more tilting than the right side in both men and women.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.146.206.0