Aeration strength analysis of overflow weir in siphon well based on numerical simulation of water-air two-phase flow  

在线阅读下载全文

作  者:Da Liu Hui Lin Bensheng Huang Xiangju Cheng Lubin Sun 

机构地区:[1]Institute of Water Resources and Water Ecological Environment Engineering,Guangdong Research Institute of Water Resources and Hydropower,Guangzhou,China [2]School of Civil Engineering and Transportation,South China University of Technology,Guangzhou,China

出  处:《River》2023年第4期433-444,共12页江河(英文)

摘  要:The phenomenon of water aeration is serious after the overflow weir in the siphon well at the cooling water circulation system of coastal power plants.At present,designing special hydraulic structures is an effective way to reduce the intensity of aeration.In this paper,three engineering structure schemes were designed,and the three-dimensional Realizable k-ε turbulence model was used.The volume of fluid method was introduced to capture the free water surface,and the unstructured grid was used to construct the two-phase turbulent flow field.The aeration concentration and pressure distribution,obtained by numerical simulation,were basically consistent with the physical model test results.The results showed that the flow field at the orifice plates of cases 1 and 2 changed drastically,and the turbulent kinetic energy downstream of the orifice plate decreased with the increase of the number of holes.As for case 3,it showed that the high-speed water flow fell into the water cushion pool,tumbling and sucking up a lot of air,and the turbulent kinetic energy and Reynolds stress were significantly greater than the other two cases.The hydraulic structure changed the cavitation characteristics of the downflow water,and the sequence of aeration concentration of the horizontal section was case 3>case 1>case 2.The aeration concentration was only 9.18%-17.86% in case 2.The aeration concentration at stable time is expressed as a function of the relative water depth y/y_(90) and the turbulent diffusion coefficient D.The distribution formula of aeration concentration was established,and its validity was verified by literatures.The results of this study will provide a certain reference for in-depth analysis of water-air mixing motion characteristics,and simultaneously,it will have a guiding significance for the design of siphon well defoaming engineering.

关 键 词:aeration concentration siphon well turbulent characteristics water-air two-phase flow 

分 类 号:TV1[水利工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象