检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:谢军 赵国帆 黄久鹏 王小东 贾吉龙 XIE Jun;ZHAO Guofan;HUANG Jiupeng;WANG Xiaodong;JIA Jilong(School of Civil Engineering,Hebei University of Architecture,Zhangjiakou 075000,China;Hebei Key Laboratory of Diagnosis,Reconstruction and Anti-Disaster of Civil Engineering,Zhangjiakou 075000,China)
机构地区:[1]河北建筑工程学院土木工程学院,河北张家口075000 [2]河北省土木工程诊断、改造与抗灾重点实验室,河北张家口075000
出 处:《辽宁工程技术大学学报(自然科学版)》2025年第1期17-24,共8页Journal of Liaoning Technical University (Natural Science)
基 金:国家自然科学基金项目(51878242);河北省高等学校科学技术研究项目(ZD2022066)。
摘 要:为改善预制挤塑板夹心填充墙与钢筋混凝土框架间的相互作用,开展了缩尺比为1∶2的柔性、半柔性填充摩擦耗能装配式连接填充墙框架和纯框架的低周反复加载试验,分析了预制挤塑板夹心填充墙在新型装配式连接节点下不同填充方式对框架破坏形态、滞回特性、变形等抗震性能的影响。研究结果表明:预制墙-框架间采用半柔性或柔性填充装配式连接与空框架相比,抗震性能有所提升;预制墙-框架间采用半柔性与柔性填充装配式连接相比,在延性、承载力退化方面相差无几,而在框架裂缝开展、刚度、承载力等方面前者表现得更加优越。因此在预制挤塑板夹心填充墙框架间应采用半柔性填充装配式连接构造方式。In order to improve the interaction between prefabricated extruded panel sandwich infill walls and reinforced concrete frames,low circumferential repeated loading tests of flexible and semi-flexible infill friction energy-consuming assembled connection infill wall frames with a scaling ratio of 1∶2 and pure frames were carried out,and the main study analyzed the effects of different infilling methods of the prefabricated extruded panel sandwich infill walls under the new assembled connection nodes on the seismic performance of the frames in terms of damage patterns,hysteresis characteristics,deformation,and other seismic performances.The results show that the seismic performance of prefabricated walls-frames with semi-flexible or flexible infill assembly connection is improved compared with that of empty frames,while the difference between prefabricated walls-frames with semi-flexible and flexible infill assembly connection is not much in terms of ductility and bearing capacity degradation,and the former performs much better in terms of framing crack development,stiffness,and bearing capacity.Therefore,semi-flexible infill assembly connection should be used between the frames of prefabricated extruded panel sandwich infill walls.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38