Utilizing mesenteric near-infrared reflectance spectroscopy to predict gastrointestinal complication risks and optimize feeding strategies in infants undergoing cardiac surgery  

在线阅读下载全文

作  者:Wenpeng Xie Yinan Liu Yating Zeng Yirong Zheng Qiang Chen 

机构地区:[1]Department of Cardiac Surgery,Fujian Children’s Hospital(Fujian Branch of Shanghai Children’s Medical Center),College of Clinical Medicine for Obstetrics&Gynecology and Pediatrics,Fujian Medical University,Fuzhou,China

出  处:《Pediatric Investigation》2024年第4期287-294,共8页儿科学研究(英文)

摘  要:Importance: Gastrointestinal complications are common perioperative complications in children with congenital heart disease (CHD), and as near-infrared reflectance spectroscopy (NIRS) provides a non-invasive, real-time monitoring of regional tissue oxygenation, we envisioned monitoring and preventing the development of gastrointestinal complications through the use of NIRS. Objective: To assess the utility of NIRS for predicting gastrointestinal complication risks and determining optimal initial feeding times in infants post-cardiac surgery. Methods: This retrospective study included 65 infants with CHD treated at our hospital from January 2021 to January 2022. We collected and analyzed data on mesenteric regional venous and arterial oxygen saturation, arterial partial pressure of oxygen, first lactic acid levels, timing of initial enteral feeding, and incidence of gastrointestinal complications. Results: Out of 65, 61 infants were eligible for inclusion (four cases were excluded). Infants with gastrointestinal complications post-surgery showed significantly lower mesenteric NIRS values and earlier feeding times compared to those without complications (55.5 ± 3.3 vs. 59.6 ± 6.3, P = 0.029;and 59.8 ± 6.7 vs. 66.9 ± 5.7, P = 0.002, respectively). Multivariable binary logistic regression analysis revealed that mesenteric NIRS readings at the time of initial feeding independently predicted gastrointestinal complications (odds ratio, 0.802;95% confidence interval, 0.693–0.928;P = 0.003). receiver operating characteristic curve analysis indicated a significant predictive value of mesenteric NIRS at initial feeding time (area under the curve: 0.799), with a suggested critical threshold of 63.1% (93% sensitivity, 70% specificity). Pearson correlation test confirmed a significant association between mesenteric NIRS at initial feeding time and the establishment of enteral feeding. Interpretation: Mesenteric NIRS measurements at the time of initial feeding provide a reliable method for identifying infants at risk of g

关 键 词:Congenital cardiac disease Mesenteric NIRS Gastrointestinal complications Initial feeding 

分 类 号:R726.5[医药卫生—儿科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象