丁二烯抽提装置溶剂泵故障分析及处理  

AULT ANALYSIS AND TREATMENT OF SOLVENT PUMP IN BUTADIENE EXTRACTION UNIT

在线阅读下载全文

作  者:王建峰[1] 陈刚[1] 高鹏达 祖国英 梁波 Wang Jianfeng;Chen Gang;Gao Pengda;Zu Guoying;Liang Bo(PetroChina Dushanzi Petrochemical Company,Dushanzi,Xinjiang,P.C.833699)

机构地区:[1]中国石油天然气股份有限公司独山子石化分公司,新疆独山子833699

出  处:《乙烯工业》2025年第1期31-33,I0001,共4页Ethylene Industry

摘  要:丁二烯抽提装置冷却系统塔釜泵在正常操作期间,出现机泵自停情况。文中通过对机泵的工艺运行状况与密封结构、材质及润滑的分析研究,找出了冷却系统塔釜泵停机的原因,提出了有效的改进方法,使机泵运行周期得到延长,装置生产有了更好的连续性和平稳性。The tower kettle pump of the cooling system in a butadiene extraction unit automatically shut down during normal operation.Through the analysis and study on the process operation status,sealing structure,material and lubrication of the pump,this paper finds out the reasons for the shutdown of the tower kettle pump of cooling system,and puts forward some effective improvement methods,thus prolonging the operation cycle of the pump and improving the continuity and stability of unit production.

关 键 词:NMP溶剂泵 故障分析 措施 