检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐承伟 陈瑞瑞 张荣 夏亮 蓝卫 毕武喜 XU Chengwei;CHEN Ruirui;ZHANG Rong;XIA Liang;LAN Wei;BI Wuxi(PipeChina Institute of Science and Technology,Tianjin 300457,China;Tianjin Oil and Gas Transportation Branch of PipeChina Northern Pipeline Company,Tianjin 300457,China;Zhongyuan Natural Gas Co.,Ltd.of PipeChina Northern Pipeline Company,Puyang 457001,China;Cangzhou Oil and Gas Transportation Branch of PipeChina Northern Pipeline Company,Cangzhou 061001,China)
机构地区:[1]国家石油天然气管网集团科学技术研究总院分公司,天津300457 [2]国家管网集团北方管道公司天津输油气分公司,天津300457 [3]国家管网集团北方管道公司中原天然气有限责任公司,河南濮阳457001 [4]国家管网集团北方管道沧州输油气分公司,河北沧州061001
出 处:《材料保护》2025年第3期155-163,共9页Materials Protection
摘 要:交直流杂散电流干扰腐蚀已成为管道失效和破坏的主要原因之一,严重威胁管道运行安全。为了全面掌握不同交直流杂散电流干扰源的特征,以及对管道阴极保护参数的影响规律,采用试片法对某输气管道不同类型的干扰源进行长期监测。通过测试结果,分析总结了交、直流静态干扰、动态干扰及静态-动态复杂干扰等7种干扰类型的典型干扰特征,同时针对复杂的交直流混合干扰,提出人身安全、交直流混合干扰和阀室绝缘设施相应的评价指标、阈值范围及准则和推荐方法。研究成果为管道运行方迅速明确杂散电流干扰源类型,制定相应防护措施,减少复杂杂散电流干扰造成的管道腐蚀风险提供依据。AC/DC stray current interference corrosion has become one of the main causes of pipeline failure and damage,which seriously threatens the safety of pipeline operation.In order to understand the characteristics of different AC-DC stray current interference sources and their influence on the cathodic protection parameters of pipelines,the coupon method was used to monitor the interference sources of different types in a gas pipeline for a long time.Based on the test results,the typical interference characteristics of 7 types of interference types,including AC and DC static interference,dynamic interference and statically dynamic complex interference,were analyzed and summarized.Meanwhile,for complex AC and DC mixed interference,the corresponding evaluation indexes,threshold ranges,criteria and recommended methods were proposed for personal safety,AC and DC mixed interference and valve chamber insulation facilities.The research results provide a basis for pipeline operators to quickly identify the types of stray current interference sources,formulate corresponding protective measures,and reduce the risk of pipeline corrosion caused by complex stray current interference.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.127