在线阅读下载全文

作  者:王朝政 郭大鹏 胥兵周 刘畅 苗政 WANG Chaozheng;GUO Dapeng;XU Bingzhou;LIU Chang;MIAO Zheng(School of Energy Power and Mechanical Engineering,North China Electric Power University,Beijing 102206,China;State Grid Beijing Power Cable Company,Beijing 100183,China;China Railway First Group Construction and Installation Engineering Co.,Ltd.,Xi'an 710043,China;China Electric Power Research Institute,Beijing 100003,China;State Grid Electric Power Engineering Research Institute Co.,Ltd.,Beijing 100069,China)

机构地区:[1]华北电力大学能源动力与机械工程学院,北京102206 [2]国网北京市电力公司电缆分公司,北京100183 [3]中铁一局集团建筑安装工程有限公司,西安710043 [4]中国电力科学研究院有限公司,北京100192 [5]国网电力工程研究院有限公司,北京100069

出  处:《清华大学学报(自然科学版)》2025年第3期532-546,共15页Journal of Tsinghua University(Science and Technology)

基  金:国家自然科学基金项目(52104198);北京市自然科学基金项目(8232014);中国电力科学研究院有限公司研究开发项目(GC83-23-004)。

摘  要:为揭示城市高压电缆隧道网络化结构对火灾蔓延特性的影响机制,并为电缆隧道的火灾防控与结构设计提供依据,该文通过在某城市地下电缆隧道开展全尺寸现场试验,并利用火灾动力学数值模拟构建了不同隧道结构特性与通风系统耦合的火灾蔓延模型。该文模拟分析了各工况下的电缆隧道火灾过程,对比分析了模拟数据与试验数据,并研究不同工况下火灾发生时烟气的扩散行为、火焰蔓延速度以及温度分布规律。结果表明:多根多层电缆燃烧条件下,火源上方顶棚温度迅速升高,电缆数量增加显著提升了热释放率;火源左侧的烟气在火灾初期蔓延速度较快,随着时间推移,大量外部空气的进入会引起烟气回流,导致局部温度进一步升高;多根多层电缆燃烧条件下的CO体积分数显著上升,说明该条件下燃烧效率低,产生了更多有毒气体;在火源垂直上方,不同风速条件下CO体积分数的变化呈现一定的规律,在多层电缆条件下,较高的风速能够改善气体稀释效果,从而影响CO的生成和扩散。该文揭示了电缆数量、布置层数与通风系统对隧道火灾危险性的综合影响,研究结果可为高压电缆隧道的消防设计提供技术支撑。[Objective]To better understand how the structural characteristics of urban high-voltage cable tunnel networks affect fire propagation,this study aimed to provide a scientific basis for fire prevention,control strategies,and tunnel design optimization.Specifically,fire propagation behavior under different structural configurations and ventilation systems in cable tunnels was investigated.Key fire dynamics parameters analyzed included temperature distribution,smoke propagation,flame spread speed,and toxic gas concentrations for both single-layer and multilayer cable arrangements.[Methods]The investigation relied on three-dimensional fire dynamics simulations using Fire Dynamics Simulator software to explore fire propagation in urban high-voltage cable tunnels.Various tunnel structural configurations were analyzed,including single-layer and multilayer cable arrangements,with and without ventilation systems.Critical fire parameters,such as heat release rate(HRR),ceiling temperatures above the fire source,smoke flow patterns,and toxic gas concentrations,were examined under different fire scenarios.Numerical modeling provided detailed insights into how fire dynamics interact with tunnel structural features,emphasizing the significance of cable layout and ventilation.The study also explored how ventilation affects smoke behavior,assessing its influence on fire spread,temperature,and gas emissions.[Results]The results revealed distinct differences in fire behavior depending on tunnel structure and ventilation.Multilayer cable configurations caused ceiling temperatures above the fire source to rise significantly faster and reach higher peaks within 400 s compared to single-layer arrangements.This rapid increase in temperature indicated that the denser cable arrangement boosted the HRR,resulting in greater thermal effects.Smoke propagation was highly dynamic.During the early stages,it initially spread rapidly to one side of the fire source.Ventilation systems,however,altered this behavior by reversing the smoke flow direc

关 键 词:电缆隧道 火灾蔓延 数值模拟 烟气扩散 全尺寸试验 