篦冷机密封件改造研究  

Study on Improvement of Seal of Grate Cooler

在线阅读下载全文

作  者:曹亚健 Cao Yajian(Wannian Cement Co.Ltd.,Wannian Cement Plant,Nanchang,Jiangxi 330096)

机构地区:[1]江西万年青水泥股份有限公司,江西南昌330096

出  处:《江西建材》2024年第12期317-319,共3页

摘  要:文中深入分析了江西万年青水泥股份有限公司万年水泥厂(以下简称“万年厂”)8^(#)窑篦冷机长期存在的漏料问题,详细阐述了密封件改造项目的背景、设计思路、实施过程以及改造后的效果评估。通过创新性的密封件改造,万年厂成功解决漏料难题,有效降低风机电耗,较大程度提高了熟料温度和发电量,进一步改善了水泥品质,并有效降低了员工劳动强度。同时,文中对改造过程中的技术细节、经济效益以及推广前景进行了全面探讨,以供参考。This paper conducts a thorough analysis of the persistent leakage problem of the cooler fan in 8^(#)kiln of Wanyan Cement Plant(hereinafter referred to as Wanyan Plant)of Wannian Cement Co.Ltd.,It also provides a detailed account of the background,design ideas,implementation process,and post-upgrade evaluation of the seal replacement project.By implementing innovative seal replacement,Wanyan Plant successfully solved the leakage problem and effectively reduced the electricity consumption of the fan.It also significantly improved the temperature of the clinker and the amount of electricity generated,further improved the quality of cement,and effectively reduced the labor intensity of employees.In addition,the paper also discusses the technical details,economic benefits,and prospects for promotion of the transformation process in depth,for reference.

关 键 词:篦冷机 密封件改造 漏料 节能降耗 

分 类 号:TQ172[化学工程—水泥工业]

 