装配式超高性能混凝土框架节点抗震性能有限元分析  

Finite element analysis on seismic performance of prefabricated ultra⁃high performance concrete frame joints

在线阅读下载全文

作  者:王深山 易溪 吴宏磊 江海洋 刘博 刘海东 WANG Shenshan;YI Xi;WU Honglei;JIANG Haiyang;LIU Bo;LIU Haidong(China Construction Fifth Engineering Bureau Co.,Ltd.,Shanghai 200072,China;Tongji Architectural Design(Group)Co.,Ltd.,Shanghai 200092,China;College of Civil Engineering,Tongji University,Shanghai 200092,China)

机构地区:[1]中国建筑第五工程局有限公司,上海200072 [2]同济大学建筑设计研究院(集团)有限公司,上海200092 [3]同济大学土木工程学院,上海200092

出  处:《建筑结构》2025年第4期32-37,共6页Building Structure

基  金:既有混凝土建筑改建与装配式结合的结构体系设计关键技术研发(2021KY03)。

摘  要:为解决装配式框架结构钢筋套筒连接操作繁琐、节点核心区钢筋密度大等问题,提出了一种采用超高性能混凝土浇筑核心区的新型装配式梁柱连接节点。为研究新型框架节点的抗震性能,通过有限元数值分析方法对1个整浇梁柱节点试件和2个新型装配式梁柱节点试件进行数值模拟。为了探究轴压比和核心区混凝土强度对新型框架节点抗震性能的影响规律,改变JD-1的轴压比参数为0.1、0.2、0.3、0.4以及混凝土强度为C40、C50、C60、UC120、UC140、UC160。结果表明:有限元模拟与试验结果吻合良好;提高节点核心区混凝土强度可以显著增强节点的承载能力,当UHPC强度达到UC120后,再提高UHPC强度对节点承载能力提升效果不大;随着轴压比的增大节点延性逐渐降低,节点峰值荷载变化较小,轴压比对节点承载力影响不大。In order to solve the problems such as cumbersome connection operation of steel sleeve in prefabricated frame structures and high density of steel bars in the core area of the joints,a new type of prefabricated beam⁃column connection points using ultra⁃high performance concrete pouring in the core area was proposed.In order to study the seismic performance of the new frame joints,numerical simulations were carried out on a single cast beam⁃column joint specimen and two new prefabricated beam⁃column joint specimens by finite element numerical analysis method.In order to explore the influence of the axial compression ratio and the concrete strength in the core area on the seismic performance of the new frame joints,the axial compression ratio parameters of the JD⁃1 were changed to 0.1,0.2,0.3,0.4,and the concrete strengths to C40,C50,C60,UC120,UC140 and UC160.The results show that the finite element simulation and the test results are in good agreement.Increasing the concrete strength in the core area of the point can significantly enhance the bearing capacity of the point.When the UHPC strength reaches UC120,increasing the UHPC strength has little effect on the bearing capacity of the point.With the increase of the axial compression ratio,the ductility of the joint gradually decreases,the peak load of the joint changes slightly,and the axial compression ratio has little influence on the bearing capacity of the joint.

关 键 词:超高性能混凝土 装配式梁柱节点 有限元分析 参数分析 抗震性能 

分 类 号:TU375[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象