检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:冯玉霄 曾洁 刘宇钢 黎懋亮 潘绍成 尹朝强 FENG Yu-xiao;ZENG Jie;LIU Yu-gang(Clean Combustion and Flue Gas Purification Key Laboratory of Sichuan;Dongfang Electric Group Dongfang Boiler Co.,Ltd.)
机构地区:[1]清洁燃烧与烟气净化四川省重点实验室,四川成都611731 [2]东方电气集团东方锅炉股份有限公司
出 处:《电站系统工程》2025年第2期39-41,共3页Power System Engineering
摘 要:针对某高温超高压煤粉工业锅炉项目,再热系统最大温升约70℃、最小温升约20℃的特殊供热机组参数,提出一种全新的高温超高压煤粉锅炉布置型式:只设置一级再热器,并将其布置在后竖井后烟道,再热汽温通过烟气挡板调节;不设置水平烟道,锅炉“背靠背”布置,墙式燃尽风布置型式;省煤器双烟道并联布置。布置型式紧凑、经济,锅炉效率高、排放低,此种锅炉结构可广泛应用。A new layout type of high-temperature and ultra-high pressure coal powder boiler is proposed for a certain high-temperature and ultra-high pressure industrial boiler project,which has a special heating unit parameter of a maximum temperature rise of about 70℃ and a minimum temperature rise of about 20℃ in the reheating system.Only the first stage reheater is installed and arranged in the rear flue of the rear shaft,and the reheat steam temperature is adjusted through the flue gas baffle;No horizontal flue is set,the boiler is arranged "back to back",and the wall type burnout air layout is adopted;Double flue parallel arrangement of the economizer.The layout is compact and economical,with high boiler efficiency and low emissions.This boiler structure can be widely used.
分 类 号:TK227[动力工程及工程热物理—动力机械及工程]