600 MW对冲燃烧锅炉高温硫腐蚀的控制试验研究  

Research on Control Test of High Temperature Sulfur Corrosion in 600MW Opposite Combustion Boiler

作  者:刘综绪 杨华磊 朱家英 苗文哲 程佳 贾韶琦 LIU Zong-xu;YANG Hua-lei;ZHU Jia-ying(Henan Jiuyu EPRI Electric Technology Co.,Ltd.;Henan Hezhong Electric Technology Co.,Ltd.)

机构地区:[1]河南九域恩湃电力技术有限公司,河南郑州450052 [2]河南合众电力技术有限公司

出  处:《电站系统工程》2025年第2期42-44,共3页Power System Engineering

摘  要:高参数的对冲燃烧锅炉水冷壁普遍存在高温腐蚀。以某600 MW超临界对冲燃烧锅炉为对象,依据水冷壁高温腐蚀机理,并结合锅炉实际的腐蚀状况,调整贴壁风、外二次风、煤粉细度以及风煤比,发现贴壁风对减弱还原性气氛有较为明显的作用。为有效地发挥贴壁风的作用,通过改造和试验得出不同运行氧量下的贴壁风挡板开度特性曲线。The water wall of high parameters opposed combustion boilers generally occur high temperature corrosion.Takes a 600MW supercritical opposed combustion boiler as an example,according to the high temperature corrosion mechanism of the water wall and the actual corrosion situation of the boiler,adjusts the closing-to-wall air,the external secondary air,the pulverized coal,and air coal ratio,finds that the closing-to-wall air obviously reduces the reductive atmosphere.To effectively utilize the effect of the closing-to-wall air,the characteristic curves of the closing-to-wall air baffles under different operating oxygen levels were obtained through transformation and experiments.

关 键 词:对冲燃烧锅炉 高温硫腐蚀 贴壁风 

分 类 号:TK227[动力工程及工程热物理—动力机械及工程]

 