检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Renzhong SUN Qiang FANG Huagang ZHANG Yuanjun JIANG Kejian MA Mengsi WEI Shaoyuan WU
机构地区:[1]Research Center for Space Structure,Guizhou University,Guiyang 550025,China [2]College of Civil Engineering,Guizhou University,Guiyang 550025,China [3]Guizhou Province Key Laboratory of Structural Engineering,Guiyang 550025,China [4]Sinohydro Bureau 9 Co.,Ltd.,Guiyang 550081,China
出 处:《Frontiers of Structural and Civil Engineering》2025年第2期300-317,共18页结构与土木工程前沿(英文版)
基 金:the financial support from the National Natural Science Foundation of China(Grant No.51568012);the Scientific Research Foundation of Guizhou University(GuiDaRenJiHeZi[2023]14);the Science Foundation for Youths of Education Commission of Guizhou Province(QianJiaoJi[2024]020);the Basic Research Project of Guizhou University(GuiDajiChu[2024]18).
摘 要:To address the insufficient stiffness of the V-shaped reinforced concrete folded plate structure and its construction process causing environmental pollution,a novel assembled monolithic spherical-shaped reinforced concrete ribbed folded plate structure(AMRRFS)was proposed.The advantages of AMRRFS are that its construction process is environmentally friendly while it also exhibits great stability and rigidity.Therefore,an experimental and numerical investigation were conducted on the AMRRFS to investigate its mechanical properties.In addition,the parametric analysis of the AMRRFS was conducted,and some design recommendations were proposed.Under the design load,the experimental findings revealed that AMRRFS possessed excellent mechanical properties.During the overloading phase,the interface between the in situ casting area and the prefabrication area was severely damaged,leading to the loss of the structure’s ability to bear loads.The outcomes from the finite element simulations of AMRRFS closely mirrored the results of the experimental investigation.Based on the parametric analysis,it was recommended that the height of the AMRRFS,the height of the ribs,and the height of the secondary ridge beams shall be 1/7–1/5,1/65–1/50,and 1/34–1/30 of the span,and that the minimum reinforcing ratio for all types of plates shall exceed 1.0%.
关 键 词:experimental analysis numerical analysis parametric analysis prefabricated structure concrete folded plate structure