发动机冷却系统工作流量数值模拟及提升研究  

Numerical Simulation and Improvement Research on the Working Flow Rate of Engine Cooling System

在线阅读下载全文

作  者:谭礼斌 袁越锦[1] TAN Libin;YUAN Yuejin(School of Mechanical and Electrical Engineering,ShaanXi University of Science&Technology,710021,Xi’an,Shaanxi,China)

机构地区:[1]陕西科技大学机电工程学院,陕西西安710021

出  处:《河北水利电力学院学报》2025年第1期18-24,共7页Journal of Hebei University Of Water Resources And Electric Engineering

基  金:国家自然科学基金资助项目(51876109)。

摘  要:为评估某四缸发动机冷却系统工作流量和探究影响工作流量的因素,采用GT-COOL软件搭建冷却系统工作流量一维分析模型,并基于该模型研究部件出水管径、部件流动阻力、水泵性能对工作流量的影响。结果表明:发动机转速10000 r/min时冷却系统初始状态的总流量为79.8 L/min;水泵出水管径21 mm和节温器小循环出水管径13 mm、油水交换器及散热器流动阻力各降低20%时冷却系统总流量为83.7 L/min;水泵传动比和水泵单品性能对冷却系统工作流量的影响显著。通过提升水泵单品性能和降低冷却系统总阻力,冷却系统的工作流量增加至90 L/min。经验证,发动机转速10000 r/min时冷却系统总流量实测值为88.5 L/min,与仿真预测值90 L/min间相差1.5 L/min,误差为1.7%,说明冷却系统工作流量仿真结果准确可靠。研究结果可为发动机冷却系统工作流量评估及流量提升提供理论指导。To evaluate the working flow rate of a four cylinder engine cooling system and explore the factors affecting the working flow rate,a one-dimensional analysis model of the cooling system working flow rate was constructed using GT-COOL software.Based on this model,the effects of component outlet pipe diameter,component flow resistance,and water pump performance on the working flow rate were studied.Results show that the total flow rate of the initial state of the cooling system at an engine speed of 10000 r/min is 79.8 L/min.The total flow rate of the cooling system is 83.7 L/min when the diameter of the water pump outlet pipe is 21 mm,the diameter of the small circulation outlet pipe of the thermostat is 13 mm,and the flow resistance of the oil-water exchanger and radiator is reduced by 20%respectively.The transmission ratio of water pumps and the performance of individual water pumps have a significant impact on the working flow rate of cooling systems.By improving the performance of individual water pumps and reducing the total resistance of the cooling system,the working flow rate of the cooling system is increased to 90 L/min.After verification,the measured total flow rate of the cooling system at an engine speed of 10000 r/min is 88.5 L/min,which differs from the predicted simulation value of 90 L/min by 1.5 L/min,with an error of 1.7%.This verifies the accuracy and reliability of the simulation results of the cooling system's working flow rate.The research results can provide theoretical guidance for the evaluation and improvement of the working flow rate of engine cooling systems.

关 键 词:发动机 冷却系统 工作流量 部件流阻 水泵性能 

分 类 号:U464.138[机械工程—车辆工程] TK401[交通运输工程—载运工具运用工程] TP273[交通运输工程—道路与铁道工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象