6FA型燃气轮机SFC过磁通的原因及处理方法  

Causes and Treatment Methods of SFC Over Flux of 6FA Gas Turbine

作  者:胡凯 孙新 Hu Kai;Sun Xin(Jiangsu Guoxin Gaoyou Thermal Power Co.,Ltd.,Jiangsu Gaoyou 225600,China)

机构地区:[1]江苏国信高邮热电有限责任公司,江苏高邮225600

出  处:《燃气轮机技术》2025年第1期58-61,共4页Gas Turbine Technology

摘  要:某电厂配备两套6FA型燃气-蒸汽联合循环机组,燃气轮机启动阶段采用静态变频启动装置(SFC)驱动燃气轮机发电机转动,然后通过变速齿轮箱带动燃气轮机转动。通过某公司静态变频启动装置运行过程中的故障案例分析,准确判断出故障点,提出具体解决方案,保障了静态变频启动装置的可靠运行。通过此类故障,可以给同类型发电企业遇到同样问题时,提供参考依据。A power plant was equipped with two sets of 6FA gas-steam combined cycle units.During the startup phase of the gas turbine,a static frequency converter(SFC)was used to drive the gas turbine generator to rotate,and then the variable-speed gearbox drove the gas turbine to rotate.Through the analysis of the fault cases of a certain company's static frequency converter during operation,the fault locations were accurately determined,and specific solutions were proposed to ensure the reliable operation of the static frequency converter.Such faults can serve as a reference of solution for power generation enterprises of the same type to address similar issues.

关 键 词:静态变频启动装置 电压传感器 过磁通 机桥 网桥 

分 类 号:TK478[动力工程及工程热物理—动力机械及工程]

 