摘  要:针对三点内径千分尺校准工作需配套大量标准环规、成本较高的问题,本文使用高精度光栅测长机配合专用检具和少量塞规,对其示值误差进行测量和不确定度评定,并与标准环规法的测量结果进行比对。结果表明,两种测量方法一致性较好,满足不确定度要求。In order to solve the problem that the calibration of three-point inner micrometer needs a large number of standard ring gauges and high cost,this paper uses high-precision grating length measuring machine with special gage and a few plug gauges to measure the indicating error and evaluate the uncertainty,and compares the measure-ment results with the standard ring gauge method.The results show that the two measurement methods have good consistency and meet the requirement of uncertainty.