检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Ruiliang ZHANG Yongjun SHEN Xiaotong YANG
机构地区:[1]School of Mechanical Engineering,Shijiazhuang Tiedao University,Shijiazhuang,050043,China [2]School of Traffic and Transportation,Shijiazhuang Tiedao University,Shijiazhuang,050043,China [3]State Key Laboratory of Mechanical Behavior and System Safety of Traffic Engineering Structures,Shijiazhuang Tiedao University,Shijiazhuang,050043,China
出 处:《Applied Mathematics and Mechanics(English Edition)》2025年第4期633-646,共14页应用数学和力学(英文版)
基 金:Project supported by the National Natural Science Foundation of China(Nos.12272242 and U1934201)。
摘 要:Piecewise linear systems are prevalent in engineering practice,and can be categorized into symmetric and asymmetric piecewise linear systems.Considering that symmetry is a special case of asymmetry,it is essential to investigate the broader model,namely the asymmetric piecewise linear system.The traditional averaging method is frequently used for studying nonlinear systems,particularly symmetric piecewise linear systems,with the harmonic response of the oscillator serving as a key prerequisite for calculating steady-state solutions.However,asymmetric systems inherently exhibit nonharmonic,asymmetric responses,rendering the traditional averaging method inapplicable.To overcome this limitation,this paper introduces an improved averaging method tailored for an oscillator characterized by asymmetric gaps and springs.Unlike the traditional method,which assumes a purely harmonic response,the improved averaging method redefines the system response as a superposition of a direct current(DC)term and a first harmonic component.Herein,the DC term can be regarded as the offset induced by model asymmetry.Furthermore,the DC term is treated as a slow variable function of time,with its time derivative assumed to be zero when calculating the steady-state solution,akin to the amplitude and phase in the traditional averaging method.Numerical validation demonstrates that the responses computed in both time and frequency domains with the improved averaging method exhibit greater accuracy compared with those derived from the traditional method.Leveraging these improved results,the study also examines the parameter effect,stability,and bifurcation phenomena within the amplitude-frequency responses.
关 键 词:nonlinear vibration piecewise linear system asymmetry averaging method OFFSET
分 类 号:O322[理学—一般力学与力学基础]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.198