作 者:江毅 梁韬 周靖[1,2] JIANG Yi;LIANG Tao;ZHOU Jing(School of Civil Engineering and Transportation,South China University of Technology,Guangzhou 510641,China;Engineering Seismic Research Center of Guangdong,Guangzhou 510641,China;Architectural Design Research Institute of SCUT Co.,Ltd,Guangzhou 510640,China)
机构地区:[1]华南理工大学土木与交通学院,广东广州510641 [2]广东省高校工程抗震技术研究中心,广东广州510640 [3]华南理工大学建筑设计研究院有限公司,广东广州510640
出 处:《建筑结构学报》2025年第4期44-56,共13页Journal of Building Structures
基 金:国家自然科学基金项目(52378512);广东省自然科学基金项目(2022A1515010878);华南理工大学建筑设计院有限公司科研项目(x2jz-D8220300)。
摘 要:为验证薄壁钢管螺旋箍筋笼约束高强混凝土芯柱(TSSHC)增强装配连接的可靠性,研究高轴压比装配式TSSHC增强组合剪力墙(PCCS剪力墙)的抗震性能和传力路径,考虑TSSHC数量、螺旋箍筋笼的纵筋数量和螺旋箍筋间距、接缝座浆层混凝土强度等的影响,设计6片试验轴压比约为0.33的PCCS剪力墙和1片现浇剪力墙作为对比,对其进行拟静力试验。结果表明:TSSHC抑制PCCS剪力墙水平连接性能快速退化,接缝座浆层内依次发展多道传力路径,接缝座浆层和预制墙体均有裂缝发展和分布,TSSHC发挥了可靠连接作用,装配整体性良好;PCCS剪力墙整体表现为弯剪复合破坏形态,TSSHC制约剪切斜裂缝的破坏发展,而且墙面有竖向破裂带发展,损伤破坏路径有明显规律性;在高轴压比下,PCCS剪力墙的滞回曲线饱满,峰值荷载后骨架曲线有平缓承载力下降段,塑性变形和延性良好,平均极限位移角1/67,位移延性系数均值4.20;TSSHC是影响连接性能和抗震冗余性的主要因素。依据规范方法以及试验结果,构建了高轴压比下PCCS剪力墙的斜截面受剪承载力计算方法,计算值与实测值差异小于6.5%。To verify the reliability of assembly connection enhanced by thin-walled steel-tube spiral-stirrup confined high-strength concrete cores(TSSHCs),and to investigate the seismic performance and force transmission path in the prefabricated TSSHC reinforced composite shear wall(PCCS shear wall)with high axial compression ratio,six PCCS shear wall specimens with axial compression ratio of 0.33 were designed for quasi-static tests,considering the differences of the number of TSSHCs and longitudinal bars in the steel-tube,the spacing of spiral-stirrup,and the concrete strength of the joint grouting layer.The results show that the TSSHC inhibits the rapid degradation of the horizontal connection performance of the PCCS shear walls.Multiple force transmission paths are developed successively in the joint grouting layer,and cracks are developed and distributed in both the joint grouting layer and the prefabricated concrete wall.The TSSHC plays a reliable role in connecting different parts,and the assembly integrity is satisfactory.The PCCS shear walls show a bending-shear composite failure mode.The TSSHC restricts the development of shear oblique cracks.Vertical fracture zone develops in the wall,and the damage path is regular.Under high axial compression ratio,the hysteresis curve of PCCS shear walls is full,the skeleton curve has a gentle bearing capacity decline section after peak load,and the plastic deformation ability and ductility are sufficient.The average limit displacement angle is 1/67,and the average displacement ductility coefficient is 4.20.The number of TSSHCs is the main factor affecting the assembly performance and seismic redundancy.Based on the existing standard method and test results, a calculation model of the shear capacity of PCCS shear walls under high axial compression ratio was established, and the difference between the calculated value and the test value is less than 6. 5%.
关 键 词:预制混凝土组合剪力墙 钢管混凝土 水平连接 拟静力试验 抗震性能
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33