检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨月 Yang Yue(Liuzhou Institute of Metrology and Measurement Technology,Liuzhou 545006)
机构地区:[1]柳州市计量技术测试研究所,柳州市545006
出 处:《仪器仪表标准化与计量》2025年第2期44-45,48,共3页Instrument Standardization & Metrology
摘 要:随着生活水平的日益提高,医疗现代化进程也在快速发展,多参数监护仪在诊断和治疗上的使用日益增长。本文对多参数监护仪的心电部分、无创血压部分、血氧饱和部分检定情况、检定过程中出现的问题及解决办法进行梳理,同时对结果分析、讨论,从检定操作、医疗机构和生产企业方面给出可行性操作。With the increasing improvement of living standards and the rapid development of medical modernization,the use of multi parameter monitors in diagnosis and treatment is growing day by day.The paper summarizes the importance of multi parameter monitoring devices,the calibration status of electrocardiogram,non-invasive blood pressure,and blood oxygen saturation,as well as the problems and solutions encountered during the calibration process.At the same time,the results are analyzed and discussed,and feasible operations are provided from the perspectives of calibration operations,medical institutions,and production enterprises.
关 键 词:多参数监护仪 心电 无创血压 血氧饱和度 检定 计量
分 类 号:TH77[机械工程—仪器科学与技术]