计及混合电解槽安全约束的微电网日前调度  

Day-ahead scheduling of microgrid considering safety constraints of hybrid electrolysers

在线阅读下载全文

作  者:张航 范馥麟 宋凯[1,2] 姜金海[1,2] 孙传禹 周佳龙 王正尧 薛瑞 ZHANG Hang;FAN Fulin;SONG Kai;JIANG Jinhai;SUN Chuanyu;ZHOU Jialong;WANG Zhengyao;XUE Rui(School of Electrical Engineering and Automation,Harbin Institute of Technology,Harbin 150001,China;Suzhou Research Institute,Harbin Institute of Technology,Suzhou 215104,China)

机构地区:[1]哈尔滨工业大学电气工程及自动化学院,黑龙江哈尔滨150001 [2]哈尔滨工业大学苏州研究院,江苏苏州215104

出  处:《洁净煤技术》2025年第3期62-71,共10页Clean Coal Technology

基  金:黑龙江省重点研发计划资助项目(2024ZXJ03C06)。

摘  要:利用含电解槽的微电网将可再生能源转化为氢能进行存储,是提高可再生能源消纳率的有效途径。为减缓可再生能源出力的波动性和随机性对微电网经济性和稳定性的影响,需要合理分配微电网中电解槽、电化学储能、燃料电池等关键设备的运行功率。电解槽运行时,由于隔膜无法完全隔绝氢气和氧气,所产生的气体不可避免地出现交叉,尤其在低负载运行时,氢氧交叉比例显著上升。当氢氧交叉比例超过安全极限时,可能引发爆炸等严重安全问题。因此,微电网功率分配中需要限制电解槽的运行功率下限。现有研究多采用恒定的电解槽功率下限。然而,由于电解槽的氢氧交叉比例随功率变化,且不同时段微电网运行工况差异显著,恒定电解槽功率下限的调度方法存在无法有效避免氢氧交叉比例越限和限制电解槽调节能力等潜在问题。此外,微电网中常配置碱性电解槽和质子交换膜电解槽,2种电解槽氢氧交叉比例随功率变化的特性存在显著差异,分别设定其功率下限将进一步增加调度复杂性。为解决上述问题,分析碱性和质子交换膜电解槽的运行特性,建立电解槽动态安全约束,并提出了考虑混合电解槽动态安全约束的光–氢–储微电网调度方法。仿真结果表明,与传统调度方法相比,所提方法能够有效保障电解槽安全,为含氢储能微电网优化调度提供了新的思路。Equipping microgrids with electrolysers which convert renewable energy sources(RESs)into hydrogen for storage is an efficient approach to enhancing RES consumptions.This requires rational power allocation among controllable devices,such as electrolysers,electrochemical energy storage systems and fuel cells,within microgrids so as to mitigate the impacts of RES fluctuations on system economics and stability as well as equipment safety.Since the membrane of electrolysers cannot completely separate the production of hydrogen and oxygen,the proportion of gas crossover will accumulate,especially during low-load operation,and might eventually exceed the maximum allowable limit and cause explosion.Therefore,the lower operating limits of electrolysers must be taken into account to allocate power between electrolysers and other components within microgrids.Constant lower power limits are usually specified for electrolysers to ensure their safe operation.However,the use of constant lower limits for electrolysers has certain limitations since the operating conditions of microgrids together with electrolysers dynamically change over time.A constant lower limit would be too conservative to exploit the ability of an electrolyser to absorb RESs,and sometimes may fail to prevent excessive crossover when an electrolyser operates at low loads for long time.In addition,microgrids typically incorporate both alkaline electrolysers(AELs)and proton exchange membrane(PEM)electrolysers,which exhibit distinct gas crossover characteristics.This further increases the complexity of microgrid scheduling due to the fact that lower power limits must be set for each electrolyser type separately.To address these challenges,this paper first establishes dynamic safety constraints for AEL and PEM electrolysers based on a comprehensive analysis of their operational characteristics.Then,a microgrid scheduling method is proposed to maximise the overall benefits from hydrogen production and electricity price arbitrage by optimising power allocation to a

关 键 词:微电网 电解槽 氢氧交叉 日前调度 

分 类 号:TM73[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象