空分后备液氮系统出口氮气温度异常降低原因分析及处理  

ANALYSIS AND TREATMENT OF ABNORMAL TEMPERATURE DROP IN NITROGEN GAS AT THE OUTLET OF THE BACKUP LIQUID NITROGEN SYSTEM FOR AIR SEPARATION UNITS

在线阅读下载全文

作  者:张兴 Zhang Xing(SINOPEC Jinling Branch,Nanjing 210033)

机构地区:[1]中国石化金陵分公司,江苏南京210033

出  处:《大氮肥》2025年第2期93-96,121,共5页Large Scale Nitrogenous Fertilizer Industry

摘  要:针对空分装置出现的一起后备液氮系统供氮温度异常降低事件,从设备配置、工艺参数设定、操作法编制及操作人员培训等各方面分析其发生的原因,并提出有效的应对措施及优化方案,为同类型空分装置后备液氮系统预防及处置类似故障波动,实现稳定供氮提供有效参照。This paper analyzed the causes of an abnormal temperature drop event in the nitrogen supply of the backup liquid nitrogen system for an air separation unit,considering various aspects such as equipment configuration,process parameter settings,operation procedure formulation,and operator training.Effective countermeasures and optimization plans were proposed to prevent and handle similar fluctuations in faults for backup liquid nitrogen systems in similar air separation units,providing a reference for stable nitrogen supply.

关 键 词:空分后备液氮系统 供氮温度 异常降低 处理 

分 类 号:TQ116.2[化学工程—无机化工]

 