检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Mohamed El-Mahrouk Cord Langner Robert Sucher Daniela Kniepeiss
机构地区:[1]Division of General,Visceral and Transplantation Surgery,Department of Surgery,Medical University of Graz,Graz 8036,Steiermark,Austria [2]Diagnostic and Research Institute of Pathology,Medical University of Graz,Graz 8036,Steiermark,Austria
出 处:《World Journal of Transplantation》2025年第3期257-262,共6页世界移植杂志(英文)
摘 要:BACKGROUND Hyperspectral imaging(HSI)offers useful information on organ quality and has already been successfully used in kidney and liver transplantation to assess transplanted organs.Up to now,there is no case report in the literature describing HSI for quality assessment of a machine perfused donor liver.The allocated liver from a 49-year-old female donor(161 cm,70 kg)was perfused with the OrganOx®normothermic machine perfusion system in the recommended way.Organ quality assessment was performed based on laboratory values at defined time points.In addition,the final evaluation of the liver comprised macroscopic findings and HSI of each liver segment.After discarding the organ,biopsies were taken from each segment and correlated with the results of the HSI.CASE SUMMARY The donor liver’s size(29 cm×17 cm×11 cm)and weight of 2180 g posed challenges for adequate placement within the organ container.Baseline biopsy of the liver revealed no evidence of fibrosis,steatosis or inflammation.An hour after perfusion start,measurements of the perfusate indicated a pH of 7.18,a glucose level of 404 mg/dL,and a lactate level of 1.7 mmol/L.Throughout perfusion,a significant decline in glucose levels began at the fourth hour,reaching a nadir of 20 mg/dL after eight hours.Concurrently,lactate levels steadily rose,peaking at 4.9 mmol/L after the total perfusion time of 12 hours.Macroscopic alterations(signs of congestion and reduced blood circulation)on the liver’s surface were noted,particularly pronounced in segments 2,3,and 8.HSI of these areas unveiled significant reduced oxygenation.Consequently,based on all these observations,the decision was made to discard the organ.Histological examination of the altered regions revealed congestion,necrotic changes,and dissociation of CONCLUSION This case report describes the integration of HSI in the decision making of the decline of a 49-year-old machine perfused donor liver.HSI offered useful information concerning the tissue morphology and graft viability and could therefore
关 键 词:Liver transplantation Organ transplantation Normothermic machine perfusion Hyperspectral imaging Case report
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63