检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:康胜军 何志堂 赵丕 汪健[2] 史志刚 KANG Shengjun;HE Zhitang;ZHAO Pi;WANG Jian;SHI Zhigang(The First Geodetic Surveying Brigade of Ministry of Natural Resources,Xi'an 710054,Shaanxi,China;Key Laboratory of Earthquake Geodesy,Institute of Seismology,China Earthquake Administration,Wuhan 430071,Hubei,China)
机构地区:[1]自然资源部第一大地测量队,陕西西安710054 [2]中国地震局地震研究所地震大地测量重点实验室,湖北武汉430071
出 处:《地震研究》2025年第4期693-701,共9页Journal of Seismological Research
基 金:国家自然科学基金(42374104,41604014);陕西测绘地理信息局科技创新项目(SCK2024-02).
摘 要:为了分析测段数量对相对重力仪性能试验的影响,对2021—2024年4台CG-6型和4台BURRIS型相对重力仪的性能试验数据进行处理,选取2~9段段差计算动态精度和3种仪器组合数的一致性中误差。发现CG-6型、BURRIS型相对重力仪动态精度的均值分别为(1~3)×10-8 m/s 2、(4~16)×10-8 m/s 2;3台仪器组合较6台仪器组合的一致性中误差更容易满足限差。剔除读数异常的仪器干扰后进一步分析发现,测段数量与相对重力仪的性能试验结果密切相关。随着测段数量的增加,动态精度和一致性中误差结果会逐渐趋于稳定;当测段数量为5~7段时,各台仪器的动态精度和多台仪器一致性中误差达到峰值,之后逐渐减小或保持稳定。In order to analyze the influence of the number of gravimetric sections on the performance test of the relative gravimeter,the performance test data of four CG-6 and four BURRIS relative gravimeters for four consecutive years were processed,and the difference between 2 to 9 sections was selected to calculate dynamic accuracy and the mean square error of the consistency of multiple instruments of the three instrument combinations.It was found that the dynamic accuracy of CG-6 relative gravimeter changed in the range of 1×10-8 m/s 2 to 3×10-8 m/s 2,and the dynamic accuracy of BURRIS relative gravimeter was in the range of 4×10-8 m/s 2 to 16×10-8 m/s 2.The mean square error of the consistency of three instruments is more likely to accord with the limit compared to a combination of six instruments.The results of further analysis show that the number of gravimetric sections is closely related to the performance test results of the relative gravimeter after removing the abnormal instrument interference.With the increase of the number of gravimetric sections,the dynamic accuracy and the mean square error of the consistency of multiple instruments will gradually become stable.When the number of gravimetric sections is 5 to 7,the dynamic accuracy and the mean square error of the consistency of multiple instruments reaches the peak,and then the value gradually decreases or remains stable.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49