检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Angelo Immordino Pollarolo Marco Francesco Lorusso Federico Sireci Palmira Immordino Salvatore Gallina Francesco Dispenza
机构地区:[1]Otorhinolaringology Section,Department of Biomedicine,Neuroscience and Advanced Diagnostics,AOUP Paolo Giaccone,University of Palermo,Via del Vespro,133,90127 Palermo,Italy [2]Hygiene and Preventive Medicine Section,Department of Health Promotion,Maternal and Infant Care,Internal Medicine and Medical Specialties,University of Palermo.AOUP Paolo Giaccone,University of Palermo,Via del Vespro,133,90127 Palermo,Italy [3]Otorhinolaringology Section,Department of Biomedicine,Neuroscience and Advanced Diagnostics,Azienda Ospedaliera Universitaria Policlinico‘‘Paolo Giaccone’’,University of Palermo,Via del Vespro,133,90127 Palermo,Italy
出 处:《Journal of Otology》2025年第2期93-102,共10页中华耳科学杂志(英文版)
摘 要:Background:Stapes prostheses play a crucial role in improving auditory performance and facilitating the patient's reintegration into social life.However,determining the ideal characteristics of a prosthesis and identifying the best commercially available option remain challenging.This study aims to compare the outcomes of two different types of prostheses:the MatriX Stapes Prosthesis and the new mAXIS Stapes Prosthesis.Methods:A prospective study was conducted on patients diagnosed with suspected otosclerosis who underwent stapedotomy,receiving either the MatriX or m AXIS prosthesis randomly during surgery.Postoperative follow-ups were conducted for at least one year.Audiometric evaluations were analyzed using statistical tests.Additionally,a systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Metaanalyses(PRISMA)statement.Results:The prospective study included 84 patients,divided into two groups(G1:MatriX,G2:mAXIS).The auditory results were satisfactory for both prostheses,demonstrating their effectiveness in improving hearing thresholds.We observed a gain for air conduction threshold of 26.2 dB vs 21.2 dB with an ABG closure of 20.7 dB vs and 21.2 dB in G1 and G2 respectively.The literature review encompassed 15studies,revealing overall positive outcomes with different prosthetic materials.Conclusions:The study revealed effective auditory improvement with both prostheses,yet no statistically significant differences in air-bone gap closure or average hearing gain.Titanium emerged as the preferred material due to its biocompatibility,lightweight nature,and stability under magnetic resonance imaging.The mAXIS prosthesis is introduced as a cost-effective alternative with favorable intraoperative features.
关 键 词:STAPEDOTOMY stapes surgery stapes prostheses systematic review
分 类 号:R764.9[医药卫生—耳鼻咽喉科]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.200