作 者:陈蓓蓓 杨光冠[2] 张占恩[1,2] CHEN Beibei;YANG Guangguan;ZHANG Zhan’en(College of Environmental Science and Engineering,Suzhou University of Science and Technology,Suzhou 215009,China;Jiangsu Key Laboratory of Environmental Science and Engineering,Suzhou University of Science and Technology,Suzhou 215009,China)
机构地区:[1]苏州科技大学环境科学与工程学院,苏州215009 [2]苏州科技大学,江苏省环境科学与工程重点实验室,苏州215009
出 处:《理化检验(化学分册)》2025年第4期424-429,共6页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
摘 要:取10 mL处理后的样品(p H 6.0)置于15 mL离心管中,加入0.2 mL 2 g·L^(-1)吡咯烷基二硫代氨基甲酸铵溶液和0.3 mL低共熔溶剂(由物质的量比1∶1∶1的壬酸-癸酸-十二酸混合溶液制备而成),涡旋3 min,超声3 min,离心4 min,收集0.1 mL上层有机相置于1 mL石墨炉自动取样杯中,采用连续光源石墨炉原子吸收光谱法测定其中镉(以Cd^(2+)计)的含量。结果表明,镉的质量浓度在0.05~3.00μg·L^(-1)内与对应的吸光度呈线性关系,检出限(3s/k)为0.01μg·L^(-1)。对不同样品溶液测定,测定值的相对标准偏差(n=10)均小于7.0%。按照标准加入法对实际样品进行回收试验,回收率为96.6%~103%。将此方法用于检测水体和大气颗粒物中的痕量镉,得到水体中镉的检出量为0.105~0.622μg·L^(-1),大气颗粒物中镉的检出量为0.090~0.168μg·L^(-1)。The processed sample(pH 6.0,10 mL)was taken and placed in a 15 mL-centrifuge tube.0.2 mL of 2 g·L^(-1) ammonium pyrrolidine dithiocarbamate solution and 0.3 mL of deep eutectic solvent(prepared by the mixed solution of nonanoic acid,decanoic acid and dodecanoic acid at a molar ratio of 1∶1∶1)were added.The mixture was vortexed for 3 min,ultrasound for 3 min,and centrifuged for 4 min.0.1 mL of upper organic phase was taken and placed in a 1 mL-graphite furnace automatic sampling cup,and cadmium(calculated as Cd^(2+))was determined by continuous light source graphite furnace atomic absorption spectrometry.As shown by the results,linear relationship between the corresponding absorbance and mass concentration of cadmium was found in the range of 0.05-3.00μg·L^(-1),with detection limit(3s/k)of 0.01μg·L^(-1).RSDs(n=10)of the determined values for different sample solutions were less than 7.0%.Test for recovery was made by standard addition method on actual samples,giving results in the range of 96.6%-103%.This method was applied to the determination of trace cadmium in water body and atmospheric particles,with detection amounts of cadmium in water body in the range of 0.105-0.622μg·L^(-1),and detection amounts of cadmium in atmospheric particles in the range of 0.090-0.168μg·L^(-1).
关 键 词:低共熔溶剂 分散液液微萃取 连续光源石墨炉原子吸收光谱法 吡咯烷基二硫代氨基甲酸铵 镉
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7