检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:熊丽萍 赵一敏 王瑶[3] 李小燕 XIONG Liping;ZHAO Yimin;WANG Yao;LI Xiaoyan(School of Petrochemical Engineering,Zhejiang International Maritime College,Zhoushan 316021,China;Tianneng Battery Group Co.,Ltd.,Huzhou 313000,China;Xinjiang Institute of Ecology and Geography,Chinese Academy of Sciences,Urumqi 830011,China)
机构地区:[1]浙江国际海运职业技术学院石油化工学院,舟山316021 [2]天能电池集团股份有限公司,湖州313000 [3]中国科学院新疆生态与地理研究所,乌鲁木齐830011
出 处:《理化检验(化学分册)》2025年第4期463-468,共6页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基 金:2020年度浙江省重点研发计划项目(2020A01006)。
摘 要:取0.2000 g土壤样品置于50 mL聚四氟乙烯消解管中,用少量水润湿,以4.5 mL盐酸、1.5 mL硝酸、3 mL氢氟酸和1 mL高氯酸为消解体系,于全自动石墨炉消解仪中按照程序进行消解,取出冷却10 min,用5%(体积分数)硝酸溶液定容至25 mL,分取2.5 mL,用2%(体积分数)硝酸溶液定容至25 mL,与10μg·L^(-1)的185Re、103Rh混合内标溶液在线混合后,采用电感耦合等离子体质谱法测定砷、铜、铅、锌、铬、镉、镍等7种重金属元素的含量。结果表明:7种重金属元素的质量浓度在一定范围内和对应的信号强度与内标信号强度比呈线性关系,检出限(3s)为0.008~0.07 mg·kg^(-1)。对土壤标准样品GSS-29、GSS-31、GSS-34进行准确度和精密度试验,测定值的相对误差的绝对值均小于7.0%,除镉元素外的6种重金属元素测定值的相对标准偏差(n=6)均小于5.0%;与传统的电热板消解法相比,本方法的准确度和精密度更优。The soil sample(0.2000 g)was taken and placed in a 50 mL-polytetrafluoroethylene digestion tube,and wetted with a small amount of water.4.5 mL of hydrochloric acid,1.5 mL of nitric acid,3 mL of hydrofluoric acid and 1 mL of perchloric acid were used as the digestion system,and the mixture was digested by a automatic graphite furnace digester according to the program.The mixture was taken and cooled for 10 min,and made its volume up to 25 mL with 5%(volume fraction)nitric acid solution.An aliquot(2.5 mL)of the solution was taken,made its volume up to 25 mL with 2%(volume fraction)nitric acid solution,and mixed well online with 10μg·L^(-1) of 185Re and 103Rh internal standard solution,in which 7 heavy metal elements,including arsenic,copper,lead,zinc,chromium,cadmium,nickel were determined by inductively coupled plasma mass spectrometry.As shown by the results,linear relationships between the ratios of the corresponding signal intensity to the internal standard signal intensity and mass concentrations of 7 heavy metal elements were kept in definite ranges,with detection limits(3s)in the range of 0.008-0.07 mg·kg^(-1).Tests for accuracy and precision on the soil standard samples GSS-29,GSS-31 and GSS-34 were carried out,and the absolute values of the relative errors of the determined values were less than 7.0%,and RSDs(n=6)of the determined values of the 6 elements except cadmium were less 5.0%.Compared with the traditional electric hot plate digestion method,the accuracy and precision of this method were better.
关 键 词:电感耦合等离子体质谱法 全自动石墨消解 土壤 重金属元素
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.13