检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Vishwanath Madhava Shervegar
出 处:《Informatics and Health》2025年第1期49-62,共14页信息学与健康(英文)
摘 要:Objective:PCG represents the acoustic replay of heart sounds from the cardiac structure.To detect and analyse the different conditions of the heart,heart sound signals are essential.CVD is detected by classifiers who superficially identify the cardiac features.Abnormal sounds in systole or diastole could indicate valve stenosis or regurgitation.The presence of S3 or S4 sounds could indicate heart failure or stiffening of the heart muscle.This paper proposes a CVD detection technique using improved WST and DA classifiers.Method:The PCG was obtained from the Physionet dataset.The raw signals were pre-processed using 2D DCT.The 2D DCT was applied to a matrix containing 3000 sounds with 10000 samples.The DCT matrix was then filtered using a 20Hz–190 Hz Type II Chebyshev filter to remove the high frequency noise above 190 Hz.After filtering,the denoised PCG matrix was obtained from the DCT matrix using inverse 2D DCT.The PCG matrix was feature extracted using WST.WST produces low-frequency components by using the LPFs to filter high-frequency components.These features were then used with the DA classifier to predict the CVD.The DA classifier uses discriminant analysis pattern classification.The DA classifier learns the training PCG pattern,from WST features,and then classifies test samples as normal or abnormal.Results:The proposed method removed noise up to 99%.The 2D DCT filter provided an average noise improvement of 37.34 dB.Further tuning in filter order or attenuation level resulted in distortion of the PCG,and noise improvement declined.The DCT filter removed up to 99%of noise as per the SNR estimation.The improved WST and the DA classifier resulted in an accuracy of 99.63%.Conclusion:Comparative analysis with DNN,advocates the superiority of the proposed method.DNN classifiers provide accurate CVD classification but require a more expensive and complex GPU.The DA classifier requires only a CPU.This work demonstrated that superior CVD classification was obtained using a combination of WST features and the DA
关 键 词:PHONOCARDIOGRAM Wavelet time frequency scattering transform Discrete cosine transform Discriminant analysis Classification
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7