Spectrofluorimetric determination of terbium with terephthalic acid  被引量:1

Spectrofluorimetric determination of terbium with terephthalic acid

在线阅读下载全文

作  者:ZHAO Guohu and ZHAO JunBasic Science Department, Gansu Agricultural University, Lanzhou 730070, China 

出  处:《Rare Metals》2002年第4期255-259,共5页稀有金属(英文版)

基  金:This project is financially supported by the Natural Science Foundation of Gansu Province (No.ZR-97-21)

摘  要:A Spectrofluorimetric method has been developed for the determination ofterbium(Ⅲ) based on the formation of a complex with terephthalic acid [benzene-1, 4-dicarboxylicacid (TPA)] in slightly acidic aqueous solution in the presence of gelatin. Terbium ion can form astable complex with TPA with the stoichiometry of 1:2. The best excitation and maximum emissionwavelengths are observed at 260 nm and 545 nm, respectively. The fluorescence intensity of terbiumcomplex gets the strongest within 20 min and remains stable up to 10 h, and it is proportional toterbium(Ⅲ) concentration in the range of 4.0x10^(-5)-1.6x10^(-7) mol·L^(-1) under the optimumconditions. The fluorescence system has good selectivity, sensitivity and stability. The relativestandard deviation is still within +-4% in the presence of 1200-fold amounts of the other lanthanideions when the concentration of terbium(Ⅲ) is 1.0x10^(-6) mol·L^(-1) and common co-existing ionshardly interfere the determination. It has been applied to the direct fluorimetric determination oftrace terbium (Ⅲ) in rare earth ores and oxides.A Spectrofluorimetric method has been developed for the determination ofterbium(Ⅲ) based on the formation of a complex with terephthalic acid [benzene-1, 4-dicarboxylicacid (TPA)] in slightly acidic aqueous solution in the presence of gelatin. Terbium ion can form astable complex with TPA with the stoichiometry of 1:2. The best excitation and maximum emissionwavelengths are observed at 260 nm and 545 nm, respectively. The fluorescence intensity of terbiumcomplex gets the strongest within 20 min and remains stable up to 10 h, and it is proportional toterbium(Ⅲ) concentration in the range of 4.0x10^(-5)-1.6x10^(-7) mol·L^(-1) under the optimumconditions. The fluorescence system has good selectivity, sensitivity and stability. The relativestandard deviation is still within +-4% in the presence of 1200-fold amounts of the other lanthanideions when the concentration of terbium(Ⅲ) is 1.0x10^(-6) mol·L^(-1) and common co-existing ionshardly interfere the determination. It has been applied to the direct fluorimetric determination oftrace terbium (Ⅲ) in rare earth ores and oxides.

关 键 词:TERBIUM SPECTROFLUORIMETRY terephthalic acid GELATIN 

分 类 号:O657.3[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象