作 者:闫永胜[1] 李荷[2] 张国营[2] 陆晓华[1]
机构地区:[1]华中科技大学环境科学与工程学院,武汉430074 [2]河南省平顶山师范高等专科学校化学系,平顶山467002
出 处:《离子交换与吸附》2002年第6期564-568,共5页Ion Exchange and Adsorption
基 金:河南省自然科学基金
摘 要:在酸性条件下,建立了以薄层树脂相吸光光度法测定钼的新方法.此法灵敏度高 (ε402=1.0×105L/mol@cm),比水相光度法提高24倍 (ε水相= 4.2×103L/mol@cm),精密度好 (检测6次,RSD=1.21%).工作曲线线性范围 (25ml体积) 0~18μg,测定天然水中钼,加标回收率为95%~105%.A new method for the determination of Mo(Ⅵ) by thin layer resin phase spectrophotometry in the situation of acidity has been reported. This method has a high sensitivity (?402=1.0?05L/mol穋m), which is 24 times higher than that of liquid phase spectrophotometry (ε水相=4.2×103L/molcm). It has been proved a satisfactory precision (7.0g/25ml Mo(Ⅵ), n=6, RSD=1.21%). The Mo(Ⅵ) in natural water has been determined, the linear range (Volume 25ml) is 0~18靏 and the recovery is 95%~105%.
关 键 词:测定 薄层树脂相吸光光度法 钼 痕量分析 水样