作 者:索南加乐[1] 罗云照[1] 吴亚萍[1] 祖拉提[2]
机构地区:[1]西安交通大学电气工程学院,西安710049 [2]新疆大学
出 处:《西安交通大学学报》2003年第2期119-122,共4页Journal of Xi'an Jiaotong University
摘 要:通过对双回线非全相运行时同名相差电流的分析,提出了一种利用同名相电压降判别双回线解列运行的新方法.该方法考虑了零序电流和两回线长度不相等因素,能有效判别双回线非全相解列运行状态.仿真结果表明,该方法在双回线各种非全相并列运行状态下,修正后的差电流明显小于修正后的和电流,在各种解列运行状态下修正后的差电流大于修正后的和电流,不会发生误判.Analyzed the differential current in the same phase of doublecircuit line, a new criterion is proposed that identifies the breakup operation by comparing the voltage of the same phase. The facts, such as zerosequence current and two lines of different lengths, are taken into account, and the criterion can be adopted to identify the breakup operation state effectively. The result of EMTP simulation indicates that in a paratactic doublecircuit line the differential current adjusted in the same phase of doublecircuit line is less than the integral one, under nonfull phase operation state, once the doublcircuit line is broken up, the differential current adjusted in the same phase of doublecircuit line is more than the integral one. The technique ensures it against the erroneous judgment.
关 键 词:电压降 双回线解列运行 电力系统 继电保护 差动保护 零序电流 回线长度
分 类 号:TM773[电气工程—电力系统及自动化]