检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁涛[1] 张绍旭[1] 王玉宝[1] 唐清华[1] 张秀香[1]
出 处:《固原师专学报》2002年第6期9-11,共3页Journal of Guyuan Teachers College
摘 要:用HNO_3溶解试样,配制6种元素混合标准系列溶液,用空气-乙炔火焰原子吸收法连续测定Pb,Cd,Fe,Cu,Sb和Mn的含量。建立了优化的仪器测定条件,并进行了相关的干扰实验。方法的回收率为98.9%~102.0%,相对标准偏差为1.8%~2.5%。After the sample was dissolved by nitric acid, a series of mixed standard solutions of the six elements were made up, then the contents of lead, cadmium, iron, copper, stibium, manganese were determined successively by air- acetylene fire atomic absorption spectrometry (FAAS) .The optimum determination conditions have been established. The interference tests for other elements that probably exist have been conducted.The rate of recovery is 98.9% - 102.0% .the relative standard deviation is 1.8% - 2. 5%.
关 键 词:火焰原子吸收法 高纯锌 PB CD FE CU SB Mn 含量测定 电镀材料 有害成分
分 类 号:TG146.13[一般工业技术—材料科学与工程] TG1[金属学及工艺—金属材料]