离子选择电极法和离子色谱法测定水中氟化物的比较  被引量:28

Comparative Study on Determination of Fluoride in Water by Fluoride Ion Selecting Electrode Method and Ion Chro-matography

在线阅读下载全文

作  者:郑和辉[1] 林少彬[1] 井海宁[1] 王红伟[1] 陈昌杰[1] 

机构地区:[1]中国疾病预防控制中心环境与健康相关产品安全所,北京100021

出  处:《环境与健康杂志》2003年第1期37-39,共3页Journal of Environment and Health

基  金:国家自然科学基金重点资助项目(39730390)

摘  要:目的比较离子选择电极法和离子色谱法测定水中氟化物是否差异有显著性。方法以离子选择电极法和离子色谱法检测了内蒙和天津两个饮水高氟地区的38口井的井水含氟量。利用SAS软件对两种方法测定结果进行了配对t检验。结果检验结果显示差异均值为0.12,随机偏差的P是0.0184,即变量DIFF显著地不同于零。结论离子色谱法测定水中氟化物含量比离子选择电极法测定结果稍高。用离子色谱法测定水氟含量可以节省时间,并获得多种其他阴离子含量。Objective To compare the fluoride ion selecting electrode(FISE)method with ion chromatography(IC)method for determination of F - in water.Methods The fluoride content in38well-water samples collected from2area s with high levels of fluoride in drinking water of Inner-Mongolia and Tianjin were detected using the FISE method and IC method.The results as matched data were tested with t-test.Results The results indicated that mean DIFF was0.12,Prob>|t|=0.0184.Con clu sion The determination of F - using IC gave a slightly higher values than that of FISE.Fluoride content in water could be determined more quickly using the IC method,and the contents of other anions could also be simultaneously deter-mined.

关 键 词:离子选择电极法 离子色谱法 氟化物 饮用水 

分 类 号:TU991.21[建筑科学—市政工程] R123.1[医药卫生—环境卫生学]

 