不结露条件下建筑外墙传热系数的确定及结露问题的探讨  被引量:2

Determination of the Heat Transfer Coefficient of Building Exterior Wall under the Non-Dewfall Condition and Discussion on the Dewfall Problems

作  者:白莉 刘晔[1] 姜志刚 

机构地区:[1]吉林建筑工程学院城建系

出  处:《吉林建筑工程学院学报》1997年第2期19-22,共4页Journal of Jilin Architectural and Civil Engineering

摘  要:本文在建筑物外墙内表面温度大于室内空气露点温度的条件下,对结露问题做了实质性的讨论.利用空气温度和湿度两个参数,在焓湿图上确定了保证在建筑物外墙内表面上不出现结露的空气状态点,并在此基础上导出了不发生结露条件下外墙的最大允许传热系数计算公式.The dew condensation problems have been substantially discussed under the condition that the inside surface temperature of exterior wall is higher than that of the indoor dewpoint. The air state point, which ensures that the dew condensation does not occur on the inside surface of exterior wall, has been determined in enthalpy-moisture chart by using two parameters of indoor air temperature and relative humidity. And on this basis, the calculating formula of the maximum heat transfer coefficient of building exterior wall under the non-dewfall condition has been derived in this paper.

关 键 词:建筑外墙 传热系数 结露 露点 最小热阻 

分 类 号:TU111[建筑科学—建筑理论]

 